Issued September 2017
Safety Messages and Decals
Copyright 2017, Heil Environmental
Printed in U.S.A.
34
LOOK UP AND LIVE. MAKE SURE
there is enough clearance between a lowered or raised container and overhead
power lines. It is not necessary for the unit or container to touch the electric cable for the electricity to pass through
the unit. See Tables 1 and 2.
STAY IN THE CAB
and
KEEP AWAY FROM ALL METAL PARTS OF THE UNIT
if the unit does touch a power line.
STAY IN THE UNIT UNTIL HELP ARRIVES.
OVERHEAD CLEARANCES
NOTICE
Table 1 and 2 is in accordance with OSHA 29CFR 1910.333. (Also refer to ANSI Standard B30.5-2004, 5-3.4.5.) If local
rules and laws require more clearance, you must follow them.
Table 1. Overhead Clearances When Operating the Unit
Voltage of Electric Line
Minimum Clearance
50,000 or less
10 feet (3 m)
Above 50,000 to 200,000
15 feet (4.6m)
Above 200,000 to 350,000
20 feet (6.1 m)
Above 350,000 to 500,000
25 feet (7.6 m)
Above 500,000 to 750,000
35 feet (10.7 m)
Above 750,000 to 1,000,000
45 feet (13.7 m)
Table 2. Overhead Clearances When Driving the Unit
Voltage of Electric Line
Minimum Clearance
750 or less
4 feet (1.2 m)
Above 750 to 50,000
6 feet (1.8 m)
Above 50,000 to 345,000
10 feet (3 m)
Above 345,000 to 750,000
16 feet (4.9 m)
Summary of Contents for PT 1000
Page 8: ...NOTES...
Page 10: ...NOTES 2...
Page 36: ...NOTES 28...
Page 64: ...NOTES 56...
Page 68: ...NOTES 60...
Page 84: ...NOTES 76...
Page 90: ...NOTES 82...
Page 150: ...NOTES 142...
Page 154: ...NOTES 146...
Page 158: ...NOTES 150...
Page 162: ...NOTES 154...
Page 200: ...NOTES 192...