Installation
Suprasetter A52/A75 – Installation
Fig. 46 Eccentric
Fig. 47 Hose
Guide the eccentric (Fig. 46/3) with the pin
upwards through the (right) hole (Fig. 46/1) and
hook the pin (Fig. 46/2) into the eye of the spring
hanging down.
Tighten the spring by turning the large wheel of the
insertion tool by approx. 1/2 turn in clockwise
direction as far as the stop.
Undo the eccentric with the small wheel of the
insertion tool, it remains in the Suprasetter.
NOTICE
Leaking coolant
Immediately wipe off any spilled coolant. Make sure no coolant reaches the PCB
(Fig. 44/3)!
Take out the hose (Fig. 47/1).
To pull a hose out of its holder, first push the hose
slightly into the holder, then hold the ring (Fig. 47/
2) in the direction of the arrow and pull out the
hose (Fig. 47/1).
NOTICE
Do not twist the hoses (Fig. 48/2).