15
or decrease the set point, simply use the up or down arrow buttons.
Press and release button
‘L2’ to display the temperature set point for heat pump circuit 2 operation. To increase
or decrease the set point, simply use the up or down arrow buttons.
To achieve proper stage control, circuit 2 would normally be set 1C below the setting for circuit 1.
It will take a very long time, as long as 24 hours, for the pool water temperature to rise or fall even one degree in
temperature. It is therefore very important not to change the temperature setting more than one degree per day,
otherwise the temperature balance may be lost.
ABOUT THE HEATSTAR CONTROL PANEL
‘POWER’ NEON -
This neon, when lit, indicates that mains electricity is being supplied to the Heatstar unit.
‘POOL WATER FLOW CUT-OUT’ NEON -
This neon, when lit, indicates insufficient pool water flow through the Heatstar unit. Should this light, please refer
to fault finding.
No pool water heating is possible until the pool water flow has been restored.
‘SYSTEM CUT-OUT’ NEON -
This neon, when lit, indicates that the refrigeration system has Cut-Out due to either a high or low internal
refrigerant pressure.
Should this light, please refer to Fault finding. No pool water heating is possible until the cut-out has been re-set.
‘DE-FROST’ NEON -
This neon, when lit, indicates that the Heatstar unit has sensed an excessive build up of ice on the cold
refrigerated air coil and is acting to regulate ice formation.
‘HEATING’ NEON -
The neon, when lit, indicates that POOL WATER HEATING is switched
‘ON’ to achieve the pool water
temperature setting.
AQUARIUS MODELS 6,8 & 16 :
These models have twin heat pump circuits, so there will be two neons for system cut-out, de-frost and heating,
one for each circuit.
‘Plus’ Version with booster heater :
These models have two additional neons below the temperature control, one green and one red.
This green neon indicates when the booster heater is operating and the red neon indicates if the booster heater
has tripped out because of an unusually high temperature in the heater.
To re-set the trip, simply switch electricity off to the product and switch it back on again.
If the tripping persists, then consult Heatstar for advice.
Please note :
All neon indicators will glow dimly even when they are not lit and this is quite normal.