4
2.0 INSTALLATION - GENERAL REQUIREMENTS
2.1 National Wiring rules may contain restrictions concerning the installation
of these units in bathrooms.
2.2 The unit should be vertically mounted on a level surface. Four mounting
feet are provided (make sure the unit is resting fully on all four supporting
feet).
2.3 Ensure the supporting surface is of sufficient strength to support the full
weight of the unit (see Technical Data).
2.4 Enough space should be left either side of the unit for adequate ventilation.
The sides should be a minimun of 60 to 70mm from any wall or partition.
If building into an enclosed cabinet ensure that adequate ventilation is
provided into the cabinet by the addition of suitable louvre panels.
2.5 The water chiller must be installed inside a building, DO NOT install
outside or in a position where it could be influenced by inclement weather
conditions.
2.6 DO NOT install where the unit may be exposed to extremes of temperature
(minimum operating temperature 10°C, maximum 45°C) or in direct
sunlight.
3.0 INSTALLATION - ELECTRICAL REQUIREMENTS
WARNING: This appliance must be earthed. It is suitable for a.c. supply only.
Disconnect the electrical supply before accessing the cabinet. Installation
must be in accordance with the current I.E.E. Wiring Regulations.
3.1 The unit is supplied fitted with a 2m 3 core 1.5mm2 flexible cable. The
electicity supply should be fused 3 Amp. Connection to the electricity
supply must be via a double pole isolating switch with a contact separation
of at least 3mm in both poles. Refer to the schematic wiring diagram
below.
3.2 The wires are colour coded as follows:
Green and Yellow
EARTH
Brown
LIVE
(L)
Blue
NEUTRAL
(N)