8.0 SPARE PARTS

The following comprehensive list of spare parts are available for your SuperChill 
water chiller. Please refer to the Rating Label on the side of your water chiller 
before ordering to ensure the correct spare part is obtained.

DO  NOT  REPLACE  WITH  PARTS  NOT  RECOMMENDED  BY HEATRAE 
SADIA  - THIS  WILL   INVALIDATE  YOUR  GUARANTEE  AND MAY  RENDER  
THE  INSTALLATION  DANGEROUS.

DESCRIPTION 

CODE NO.

Counter mounting push button spout assembly .....95 604 671
Motorised fan ..............................................................95 607 905
8mm “push fit” elbow ................................................95 607 908
Thermostat ..................................................................95 612 714
Electrical cable with moulded plug ...........................95 612 679
Agitator pump ............................................................95 607 906
Pressure reducing valve .............................................95 605 024
PE Tube 8x6 .................................................................95 607 907
PE Tube 6x4 .................................................................95 607 247
6 x 1/8 bsp “push fit” connector ...............................95 607 326

9.0 USER INSTRUCTIONS

9.1   The SuperChill water chiller cools and stores water at the temperature set 

on the adjustable thermostat. This can be set to give temperatures in the 
range of 4 to 12°C. To avoid any risk of freezing when the water chiller is 
not in use for long periods during the winter months, set the thermostat 
to a higher position. 

9.2   If  the  SuperChill  water  chiller  is  fitted  with  an  in-line  filter  that  will      

remove tastes, odours and particles from the water supply, the cartridge 
will  require  periodic  replacement  to  remain  effective.  This  period  will 
depend on the water usage, however a period of six to twelve months is 
recommended. Replacement of the filter cartridge by competent personnel 
is recommended. Only replace the filter cartridge with one of the same 
design.

9.3   Chilled water is dispensed by pressing the chromed push button on the 

front of the outlet spout. Water from the spout should be dispensed into 
suitable cups, jugs or carafes. (refer to paragraph 5.7 for flow adjustment 
instructions)

9.4   A cup dispenser is available as an accessory, code 95 970 127. This can 

dispense standard plastic or paper cups with a rim diameter of between 
70 and 85mm. 

 

9.5   To ensure the SuperChill water chiller continues to operate at its optimum 

performance it should be periodically maintained in accordance with the 
instructions given under the Sections headed 6.0 MAINTENANCE.

Summary of Contents for SUPERCHILL 30B

Page 1: ...SUPERCHILL 30B Fitting Instructions and User Guide...

Page 2: ...n or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the SuperChill unit The SuperChill unit does...

Page 3: ...nsor assembly should be periodically cleaned to prevent a build up of dust or dirt on the cooling fins 1 5 The chiller must be installed vertically on a level surface 1 6 If you have purchased an inli...

Page 4: ...iller must be installed inside a building DO NOT install outside or in a position where it could be influenced by inclement weather conditions 2 6 DO NOT install where the unit may be exposed to extre...

Page 5: ...must be allowed for removal and replacement of the filter cartridge Connection of the water supply to the chiller and filter assembly is by means of an 8mm outside diameter flexible WRAS listed plast...

Page 6: ...es to flush through the filter internal pipes tank and fittings of any air dust or debris that may have accumulated during transit or installation 5 6 Check that the filler spout is positioned at an a...

Page 7: ...umstances evaporation salts may have accumulated around the outlet points This should be cleaned with a proprietary scale remover approved for sanitary ware Ensure all traces of the cleaner are remove...

Page 8: ...ia a small pump 6 3 4 Start the pump and operate the outlet to allow the disinfecting solution to enter the chiller Allow approximately 4 litres of solution to enter the chiller to ensure the chilling...

Page 9: ...tank 6 High ambient temperatire 45 C 6 At high ambient temperatures it is normal for the unit to work continuosly Compressor works continuosly but water is not cold 1 Gas leak from the cooling system...

Page 10: ...the water chiller is not in use for long periods during the winter months set the thermostat to a higher position 9 2 If the SuperChill water chiller is fitted with an in line filter that will remove...

Page 11: ...tions The unit has been used only for chilling potable water The unit is not 4 guaranteed against damage by frost or due to the build up of scale The guarantee does not cover the filter 10 0 ENVIRONME...

Page 12: ...Mail sales ewh co uk SPD Units 9 10 Hexagon Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 020 8606 3567 Parts Center Tel 0845 2709800 www partscenter co uk Newey Eyre Specialist Produc...