6.2.3 Remove any dust or dirt using a vacuum cleaner. Particular attention should 

be paid to the inside of the louvre grills and the condensor fins. DO NOT 
use a metal brush to clean the condensor fins as they may be damaged.

6.3 DISINFECTING

It is recommended that the chiller is disinfected on a regular basis to prevent 
the build up of contaminants.

WARNING  Many disinfecting products are acid or alkali corrosive substances. 
Always follow the manufacturers instructions for use and DO NOT exceed 
the recommended dosing concentrations or times. Always wear suitable 
protective clothing, disposable gloves and safety glasses are a minimum 
requirement for most solutions.

6.3.1  Prepare the disinfecting solution in accordance with the manufacturers 

instructions. At least 5 litres of mixed solution will be required.

6.3.2 If fitted with a chlorine filter the filter cartridge must be bypassed.
6.3.3 Connect the container holding the disinfecting solution to the inlet of the 

water chiller via a small pump. 

6.3.4 Start the pump and operate the outlet to allow the disinfecting solution to 

enter the chiller. Allow approximately 4 litres of solution to enter the chiller 
to ensure the chilling coil and all internal pipework is filled with disinfecting 
solution. Close the outlets and stop the pump.

6.3.5 Allow the solution to stand within the chiller for the recommended dosing 

time (refer to manufacturers instructions).

6.3.5 Disconnect the disinfecting solution filling arrangement. Reconnect the 

chlorine filter or fit a new filter cartridge. Reconnect the mains water supply 
and turn it on.

6.3.6 At least 15 litres of water should be flushed through the chiller and outlets 

to ensure all traces of the disinfecting solution are removed from the system 
before further use for drinking water.

6.3.7 Other disinfecting processes may be suitable (eg. ozone treatment), consult 

the manufacturers for further advice.

6.4  EMPTYING ICE BANK CONTAINER

6.4.1 Disconnect mains cable from the socket. To empty the ice bank you can 

unclip the clear tube at the rear of the unit: Allow the water to flow from 
the unit into a recepticle or drain. Once flow has stopped replace the tube 
back into clips.

Summary of Contents for SUPERCHILL 30B

Page 1: ...SUPERCHILL 30B Fitting Instructions and User Guide...

Page 2: ...n or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the SuperChill unit The SuperChill unit does...

Page 3: ...nsor assembly should be periodically cleaned to prevent a build up of dust or dirt on the cooling fins 1 5 The chiller must be installed vertically on a level surface 1 6 If you have purchased an inli...

Page 4: ...iller must be installed inside a building DO NOT install outside or in a position where it could be influenced by inclement weather conditions 2 6 DO NOT install where the unit may be exposed to extre...

Page 5: ...must be allowed for removal and replacement of the filter cartridge Connection of the water supply to the chiller and filter assembly is by means of an 8mm outside diameter flexible WRAS listed plast...

Page 6: ...es to flush through the filter internal pipes tank and fittings of any air dust or debris that may have accumulated during transit or installation 5 6 Check that the filler spout is positioned at an a...

Page 7: ...umstances evaporation salts may have accumulated around the outlet points This should be cleaned with a proprietary scale remover approved for sanitary ware Ensure all traces of the cleaner are remove...

Page 8: ...ia a small pump 6 3 4 Start the pump and operate the outlet to allow the disinfecting solution to enter the chiller Allow approximately 4 litres of solution to enter the chiller to ensure the chilling...

Page 9: ...tank 6 High ambient temperatire 45 C 6 At high ambient temperatures it is normal for the unit to work continuosly Compressor works continuosly but water is not cold 1 Gas leak from the cooling system...

Page 10: ...the water chiller is not in use for long periods during the winter months set the thermostat to a higher position 9 2 If the SuperChill water chiller is fitted with an in line filter that will remove...

Page 11: ...tions The unit has been used only for chilling potable water The unit is not 4 guaranteed against damage by frost or due to the build up of scale The guarantee does not cover the filter 10 0 ENVIRONME...

Page 12: ...Mail sales ewh co uk SPD Units 9 10 Hexagon Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 020 8606 3567 Parts Center Tel 0845 2709800 www partscenter co uk Newey Eyre Specialist Produc...

Reviews: