2
The SuperChill unit must be installed and commissioned by a competent person.
Please read and understand these instructions before installing the SuperChill
unit. Following installation and commissioning, the operation of the SuperChill
unit should be explained to the user and these instructions left with them for
future reference.
The SuperChill unit is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the SuperChill
unit.
The SuperChill unit does not contain any substances harmful to health; it does
not contain any asbestos.
PACK CONTENTS
SuperChill 30B
•
Jug Filling Spout
•
3pin Plug & 2m Cable
•
Pipe & Connections
•
Pressure reducing valve
•
TECHNICAL DATA
Electrical rating ..................................................180W/196W 230/240V
Compressor power .............................................1/12 HP
Chilled water output ...........................................30 l/hour (6.6gal/hour)
Nominal water outlet temperature ...................10°C
Weight (full) .........................................................27kg
Rated pressure ....................................................0.3 MPa (3.0 bar)
Minimum recommended supply pressure ........0.1 MPa (1 bar)
Refridgerant gas/gas charge weight .................R134A/140g
Operating temperature range ...........................min. 10°C/max 45°C