Heatrae Sadia Multipoint 10 and 15 litre Fitting Instructions Manual Download Page 9

9

the pressure relief device and that this pipe must 

be left open to the atmosphere. The pressure 

relief device is to be operated regularly to 

remove lime deposits and to verify that it is not 

blocked.

 

`

The pipe material should be capable of 

conveying water/steam at 100°C.

 

`

The  final  discharge  point  should  be  in  a  safe, 

visible position.

6.3 Electrical connections

WARNING

 

`

Disconnect from the mains 

electrical supply before removing 

any covers.

 

`

This product must be earthed. It is 

suitable for a.c. supply only. 

 

`

Disconnect the electrical supply 

before removing the terminal 

cover. 

 

`

Installation must be in accordance 

with the current I.E.E. Wiring 

Regulations.

 

`

The  product  is  supplied  fitted  with  a  0.75m  3 

core 1.5mm

2

  flexible  cable  on  the  3kW  model 

or a 0.75m 3 core 2.5mm

2

 cable on the 4.5kW 

model. The electricity supply should be fused 13 

Amp for a 3kW model and 20 Amp for a 4.5kW 

model and be via a double pole isolating switch 

with a contact separation of at least 3mm in both 

poles. Refer to the schematic wiring diagrams 

below.

The wires are colour coded as follows:

Green and Yellow  

EARTH  

Brown   

 

LIVE (L)

Blue 

 

  NEUTRAL 

(N)

Summary of Contents for Multipoint 10 and 15 litre

Page 1: ...Multipoint 10 and 15 litre Fitting Instructions...

Page 2: ...cise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 S...

Page 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Page 4: ...in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation and hot water could lead t...

Page 5: ...maintained and disposed of at end of life See Section 3 11 Electrical rating 3kW 240V 2 75kW 230V 4 5kW 240V 4 1kW 230V Capacities 10 or 15 litres Weight full 10 litre 16 9kg 15 litre 23 8kg Rated pr...

Page 6: ...relief valve Pressure relief expansion valve Note If pressure reducing valve is used expansion down the mains is not possible Pressure relief expansion valve Pressure relief expansion valve Expansion...

Page 7: ...gineer in accordance with prevailing and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Wa...

Page 8: ...environment The pipe from the valves to the tundish should be 15mm o dia minimum From the tundish to the point of discharge the pipe should be 22mm o dia minimum and have a resistance to flow equivale...

Page 9: ...t be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations The pro...

Page 10: ...l After filling the installation with water in the previous section please follow the following steps to complete the installation of the product WARNING DO NOT switch on the product until it has been...

Page 11: ...d when using in conjunction with a Thermostatic Blending Valve position To lock the thermostat position the instructions given under Sections 4 2 3 or 4 2 4 should be followed We recommend that this p...

Page 12: ...y by unscrewing the five securing screws a tapped jacking point is provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean...

Page 13: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without...

Page 14: ...oduct is manufactured from many recyclable materials At the end of its useful life it should be disposed of at a Local Authority Recycling Centre to realise the full environmental benefits Insulation...

Page 15: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Page 16: ...sponsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the need to...

Reviews: