Heatrae Sadia Multipoint 10 and 15 litre Fitting Instructions Manual Download Page 15

15

Warranty

The  product  warranty  is  for  a  period  of  five  years 

from the date of purchase with the exception of the 

immersion heater and thermal controls which are 

covered for a period of two years provided:

1.    The product has been installed in accordance 

with these instructions and all necessary inlet 

controls  and  safety  valves  have  been  fitted 

correctly.

2.    Any valves or controls are of Heatrae Sadia 

recommended type.

3.    The product has not been tampered with and 

has been regularly maintained as detailed in 

these instructions.

4.    The product has been used only for heating 

potable water.

5.   Within 60 days of installation, the user completes 

and  returns  the  certificate  supplied  along  with 

proof of purchase to register the product.

The product is not covered against damage by frost 

and the immersion heater is not covered against 

excessive scale build up.

This warranty does not affect the statutory rights of 

the consumer.

Accessories

The product can be used to supply several hot water 

outlets via conventional taps. It is not recommended 

for supplying a shower. Individual site demands 

should be considered when choosing capacity and 

the number of outlets to be served.

A Thermostatic Blending Valve can be used in 

conjunction with this product. Accessory Pack U3 

(code no. 95 970 354) is recommended. Follow the 

installation instructions supplied with the valve for 

connection to the system.

Summary of Contents for Multipoint 10 and 15 litre

Page 1: ...Multipoint 10 and 15 litre Fitting Instructions...

Page 2: ...cise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 S...

Page 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Page 4: ...in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation and hot water could lead t...

Page 5: ...maintained and disposed of at end of life See Section 3 11 Electrical rating 3kW 240V 2 75kW 230V 4 5kW 240V 4 1kW 230V Capacities 10 or 15 litres Weight full 10 litre 16 9kg 15 litre 23 8kg Rated pr...

Page 6: ...relief valve Pressure relief expansion valve Note If pressure reducing valve is used expansion down the mains is not possible Pressure relief expansion valve Pressure relief expansion valve Expansion...

Page 7: ...gineer in accordance with prevailing and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Wa...

Page 8: ...environment The pipe from the valves to the tundish should be 15mm o dia minimum From the tundish to the point of discharge the pipe should be 22mm o dia minimum and have a resistance to flow equivale...

Page 9: ...t be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations The pro...

Page 10: ...l After filling the installation with water in the previous section please follow the following steps to complete the installation of the product WARNING DO NOT switch on the product until it has been...

Page 11: ...d when using in conjunction with a Thermostatic Blending Valve position To lock the thermostat position the instructions given under Sections 4 2 3 or 4 2 4 should be followed We recommend that this p...

Page 12: ...y by unscrewing the five securing screws a tapped jacking point is provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean...

Page 13: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without...

Page 14: ...oduct is manufactured from many recyclable materials At the end of its useful life it should be disposed of at a Local Authority Recycling Centre to realise the full environmental benefits Insulation...

Page 15: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Page 16: ...sponsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the need to...

Reviews: