Heatrae Sadia Multipoint 10 and 15 litre Fitting Instructions Manual Download Page 4

4

2.3

 Specific safety instructions

WARNING

DO NOT operate the  product if:

 

`

Water ceases to flow during use.

 

`

Water has entered inside the 

product because of an incorrectly 

fitted cover.

 

`

If the appliance is damaged. 

(in all cases turn off mains power and 

isolate water supply)

 

`

If water discharges from the 

temperature/pressure relief valve 

on the product shut down. Do not 

turn off any water supply. Contact 

a competent installer for unvented 

water heaters to check the system.

 

`

Do not tamper with any of the 

safety valves fitted to the system. 

If a fault is suspected contact a 

competent installer.

 

`

DO NOT bypass the thermal cut-

out in any circumstance.

2.  Safety

2.1 General safety warnings

DANGER

This product is unvented and as such 

becomes pressurised when in operation. 

The combination of pressurisation and hot 

water could lead to serious physical injury 

if the safety instructions in this manual are 

not adhered to.

DANGER

Do not install where the unit may freeze.

WARNING

 

`

Only competent persons having 

received adequate training are 

permitted to work on the product 

and the installation.

 

`

Do not tamper with the safety 

valve supplied.

 

`

Before any work, switch off the 

mains supply to the appliance.

 

`

Do not switch on if there is a 

possibility that the water in the 

appliance is frozen.

CAUTION

Do not operate immersion heater until the 

product has been filled with water.

2.2 Recommendations

CAUTION

 

`

Annual maintenance is 

recommended by a competent 

person.

Summary of Contents for Multipoint 10 and 15 litre

Page 1: ...Multipoint 10 and 15 litre Fitting Instructions...

Page 2: ...cise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 S...

Page 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Page 4: ...in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation and hot water could lead t...

Page 5: ...maintained and disposed of at end of life See Section 3 11 Electrical rating 3kW 240V 2 75kW 230V 4 5kW 240V 4 1kW 230V Capacities 10 or 15 litres Weight full 10 litre 16 9kg 15 litre 23 8kg Rated pr...

Page 6: ...relief valve Pressure relief expansion valve Note If pressure reducing valve is used expansion down the mains is not possible Pressure relief expansion valve Pressure relief expansion valve Expansion...

Page 7: ...gineer in accordance with prevailing and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Wa...

Page 8: ...environment The pipe from the valves to the tundish should be 15mm o dia minimum From the tundish to the point of discharge the pipe should be 22mm o dia minimum and have a resistance to flow equivale...

Page 9: ...t be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations The pro...

Page 10: ...l After filling the installation with water in the previous section please follow the following steps to complete the installation of the product WARNING DO NOT switch on the product until it has been...

Page 11: ...d when using in conjunction with a Thermostatic Blending Valve position To lock the thermostat position the instructions given under Sections 4 2 3 or 4 2 4 should be followed We recommend that this p...

Page 12: ...y by unscrewing the five securing screws a tapped jacking point is provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean...

Page 13: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without...

Page 14: ...oduct is manufactured from many recyclable materials At the end of its useful life it should be disposed of at a Local Authority Recycling Centre to realise the full environmental benefits Insulation...

Page 15: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Page 16: ...sponsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the need to...

Reviews: