Heatilator • HEIR36, HEIR42, HEIR50 Installation Manual • 2285-980 Rev. G • 12/14
38
B. Wiring Requirements
Intelli
fi
re
™
Plus Ignition System Wiring
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™
Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
Figure 8.3 IPI Wiring Diagram
TO JUNCTION
BOX (110V)
MODULE
I
S
FLAME
SENSE
IGNITER
GROUND
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
FLAME
MODULATION
ORANGE
WHITE
TO CUSTOMER-SUPPLIED
WALL SWITCH
JUMPER WIRE
BLACK
RED
BATTERY JUMPER WIRE
THERMOSTAT
WIRE
RED
RED
BLACK
BLACK
RC200
BATTERY PACK
6V DC