CALIBER B-VENT INSTALLATION INSTRUCTIONS
5. Wiring
a.
Optional Accessories Requirements
Wiring for optional accessories should be done
now to avoid reconstruction.
b.
Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to
the appliance junction box for operation. A
wiring diagram is shown in Figure 12.
2)
This appliance is equipped with an
intermittent pilot control valve which operates
on a 3V system.
3)
This appliance is supplied with a battery pack
and a 3VAC transformer, which requires the
installation of the supplied junction box. We
highly recommend that the junction box be
installed at this time to avoid reconstruction.
The battery pack is supplied in the
installation assembly bag. The battery pack
should be connected as shown in Figure 12
and placed on the bottom pan of the
appliance.
The battery pack requires two D cell batteries
(not included). Batteries cannot be placed in
the battery pack while using the 3 VAC
transformer. Conversely, the transformer
must be unplugged if the battery pack is used.
Figure 12 - Intermittent Pilot Ignition Wiring Diagram
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the ab-
sence of local codes, with
National Electric Code ANSI/
NFPA 70-latest edition
or the
Canadian Electric Code,
CSA C22.1
.
CAUTION:
Battery polarity must be correct or control
module damage will occur.
Note:
Optional Accessories Requirements: Wiring for
optional accessories should be done now to avoid
reconstruction.