CALIBER B-VENT INSTALLATION INSTRUCTIONS
B. LOCATION AND CLEARANCES
Dimensions
WARNING!
Due to high temperatures, the gas appliance should be located out of traffic and
away from furniture and draperies.
1. Appliance Locations and Space Requirements
Figure 1 illustrates a variety of ways the appliance
may be located in a room. The CALIBER Series may
be installed directly on the floor or raised on a hearth.
These appliances are certified for installation in a
bedroom or bed/sitting room in the U.S. and Canada,
provided that the bedroom or bed/sitting room has a
volume of at least 1600 cubic feet for the GCBC60
Series or 1750 cubic feet for the GCBC80 Series.
Figure 1 - Appliance Locations
2. Clearances
Figure 2 shows all clearances that must be
maintained around the appliance.
Figure 2
Appliance Clearances to Combustible Materials
CAUTION:
Do not expose the appliance to the elements
(such as rain, etc.).
Model
A
B
C
36 in. Series
36 in. 41 in. 24-1/2 in.
42 in. Series
42 in. 47 in. 30-1/2 in.
f i r e - p a r t s . c o m