18
R
Heatilator • ECO-ADV-PS35/50 • 7058-142D • July 21, 2010
R
1. Turn down the thermostat, let appliance completely
cool and then unplug appliance before servicing.
2. The convection blower is located on the floor at the
rear of the appliance.
3. Lift the hopper lid up until it locks into place.
4. Loosen the 4 screws on the upper back panel and
the 2 screws on the lower back panel, using a #2
Phillip Head screwdriver, a 3/8 inch wrench or a 3/8
Inch socket. Y you do not need to remove them.
Figure 18.1
.
5. Remove the left upper and lower side panels by lift
-
ing up and out. The hooks on the panels will slide
out of the slots on the appliance.
Figure 18.2.
6. Cut the wire tie holding the wires together, if applica-
ple. Model ECO-ADV-PS35 has 2 black wires and
Model ECO-ADV-PS50 has 1 black and 1 white wire
coming from the blower.
7. Remove the wing bolt and move the blower and
hold-down bracket toward the back of the appliance
to release the locating tab.
Figure 18.3
. Rotate
and pull the blower out from under the convection
plenum. Slide the blower out of the appliance. Dis
-
connenct the wires from the spade connectors at
this time.
Figure 18.4.
8. Re-install in reverse order. Be certain that the hold-
down bracket’s screws are completely seated in the
gromments or the wing bolt can not be secured in
place. Insert the locating tab into the placement slot
and re-attach the wing bolt.
Figure 18.4.
9. Attach a new wire tie to hold wires together if neces-
sary.
A. Convection Blower Replacement
4
Replacement Parts
Loosen Screws,
Do Not Remove
Figure 18.1
Figure 18.2
Figure 18.3
Figure 18.4
Wire Tie
Wing Bolt
Rotate and Pull to
Release Locating Tab
Locating Tab
Hold Down Bracket
Spade
Connectors
Upper Left
Panel
Lower Left Panel
Lift Up and Out of Slots