background image

01/04

33795 Rev i

1

INSTALLATION & OPERATING

INSTRUCTIONS

CALIBER DESIGNER

B-VENT SERIES

WARNING!

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this

manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.

CAUTION:

Do not expose the appliance to the elements (such as rain, etc.).

WARNING:

 

If the information in this manual

is not followed exactly, a fire or explosion may

result causing property damage, personal in-

jury or loss of life.

— Do not store or use gasoline or other flammable

vapors  and  liquids  in  the  vicinity  of  this  or  any

other  appliance.

— What to do if you smell gas

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately  call  your  gas  supplier  from  a

neighbor’s  phone.  Follow  the  gas  supplier’s

instructions.

• If you cannot reach your gas supplier, call the

fire  department.

— Installation and service must be performed by a

qualified  installer,  service  agency  or  the  gas

supplier.

Note: 

An arrow (

Æ

found in the text signifies change in

content.

(GBFL36 shown)

Æ

Summary of Contents for CALIBER DESIGNER B-VENT SERIES

Page 1: ...or explosion may result causing property damage personal in jury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What...

Page 2: ...dding materials etc It is imperative that the control compartment burners and circulating air passageways of the appliance be kept clean 4 This is a vented decorative gas appliance Do not burn wood or...

Page 3: ...construction stage of the home If you desire to put an appliance in your basement we recommend that you consider a direct vent gas appliance Basements always have a significant negative air pressure...

Page 4: ...f ANSI Z97 1 1984 and CPSC 16 CFR 1202 Safety Glazing Certification Council SGCC 1595 and 1597 Architectural Testing Inc Reports 02 31919 01 and 02 31917 01 This statement is in compliance with SPCS 1...

Page 5: ...d n a t s h g u o r h t e e S e c n a i l p p a 6 3 L F B G e c n a i l p p a s a g l a r u t a n t o l i p g n i d n a t s a l u s n i n e P 6 3 R C B G s a g l a r u t a n t o l i p g n i d n a t s...

Page 6: ...ble Materials 3 High Altitude Installation For U S installation appliances are tested and approved for elevations from 0 2000 feet When installing this appliance at an elevation above 2000 feet United...

Page 7: ...ppliance Slide the appliance into position and level the appliance from side to side and front to back Shim with noncombustible material as necessary Secure the appliance by bending out the nailing fl...

Page 8: ...ical Termination Vent Lengths 2 Firestop Spacer Vent Installation Frame an opening and install a firestop spacer whenever the vent penetrates a ceiling floor area as shown in Figure 6 Frame the openin...

Page 9: ...ntilation is good If the flames and smoke are forced away from the draft hood this may indicate a ventilation blockage or down draft resulting in gas spillage into the home If this occurs turn off the...

Page 10: ...Appendix F Note The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pres sures in excess of 1 2 psi 3 5...

Page 11: ...plugged if the battery pack is used Note This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70...

Page 12: ...the Romex connector feed the necessary length of wire through the connector and tighten the screws 3 Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the...

Page 13: ...63 or equivalent A high temperature sealant 1 8 inch wide minimum must be used to close off gaps between the appliance and facing to prevent cold air leaks See Figure 14 4 Combustible Mantel A combust...

Page 14: ...wool touches but does not cover the holes in the burner pan This will provide the glowing embers look See Figure 17 It is not necessary to use the entire bag Save the remainder for future use 10 Repl...

Page 15: ...ely call your gas supplier from a neighbor s phone Follow the supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the manual shutoff val...

Page 16: ...ly a fire or explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS STOP Read the safety information above on this label 1 Turn off wall switch 2 Open contr...

Page 17: ...under water Immediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Before operating thi...

Page 18: ...hrough burning the appliance open the control access panel grasp the handle and rotate to the CLOSED position Figure 19 Operating the AK14 Outside Air Kit s e u s s I s n o i t u l o S d n a s e s u a...

Page 19: ...an adjustable air shutter Your air shutter is provided in the closed position for natural gas and in the open position for propane In the event soot is accumulating in your appliance the air shutter...

Page 20: ...maining glass pieces with a shop vac DO NOT VACUUM IF PIECESAREHOT Replace glass with a Heatilator glass panel assembly only ordered through your local distributor Never use substitute material 6 Log...

Page 21: ...Switch RC SMART HTL Remote Control RC ELEC HTL Remote Control Electronic Ignition RC BATT HTL Battery Operated Remote Control Standing Pilot RCT MLT HTL Multi Function Remote Control SMART STAT HTL R...

Page 22: ...3 9 8 5 2 l e n a P s s e c c A l o r t n o C 4 1 6 1 6 2 y l b m e s s A n e e r c S t n o r F 5 9 5 6 7 2 d o o H e d i S 6 3 1 9 5 2 e c a F d n E r e w o L 7 8 5 1 6 2 y l b m e s s A s s a l G d...

Page 23: ...4 Cleaning 20 Specifications 4 Grounding 11 H High Altitude Installation 6 High Temperature Sealant 13 Hood 13 I Input Rate 9 10 Intermittent Pilot Ignition 11 15 17 J Junction Box Installation 12 L...

Page 24: ...quate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those spe...