5. Junction Box Installation Instructions
a.
Remove the junction box assembly from the valve compartment.
b.
If the box is being wired from the OUTSIDE of the appliance:
1)
Loosen two screws on the Romex connector, feed the necessary length of wire through the connector and
tighten the screws.
2)
Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the
junction box.
3)
Attach the junction box assembly to the outside of the appliance with the two screws provided.
c.
If the box is being wired from the INSIDE of the appliance;
1)
Pull the electrical wires from outside the appliance through this opening into the valve compartment.
2)
Loosen the two screws on the Romex connector, feed the necessary length of wire through the connector
and tighten the screws.
3)
Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the
junction box.
4)
Attach the junction box assembly to the inside of the appliance with the two screws provided.
d.
If the box is not to be wired at the time of appliance installation, assemble the receptacle and cover to the box
and install on the inside of the appliance.
WARNING!
This standing pilot appliance does not require a 110VAC supply for operation. Connecting the appliance/wall
switch to a 110VAC supply will cause the appliance to malfunction and destroy the valve and thermopile.
Figure 13
Standing Pilot Ignition Wiring Diagram
b. Standing Pilot Ignition
1) Appliance Requirements:
A wiring diagram is shown in Figure 13.
2) Optional Accessories Requirements:
Wiring for optional accessories should be done now to avoid
reconstruction.