01/04
7
CALIBER DESIGNER SERIES
C. FRAMING
Figure 3 shows a typical framing of this appliance using combustible materials. All required clearances to combustibles
must be adhered to.
Figure 3 - Framing
D. SETTING THE APPLIANCE
This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance
is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be
installed on a metal or wood panel extending the full width and depth of the appliance. Slide the appliance into position
and level the appliance from side-to-side and front-to-back. Shim with noncombustible material as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing
flanges have been positioned 5/8 back from the front of the appliance to allow the addition of drywall.
CAUTION:
Provide adequate clearances around the air
openings into the combustion chamber and
adequate accessibility clearances for servicing and
proper operation.
WARNING!
To prevent contact with sagging or loose insulation,
the appliance must not be installed against vapor
barriers or exposed insulation. Localized overheat-
ing could occur and a fire could result.