4
Product Specifications
Available Models:
•
Methane, 1.00% and 0.50%
•
“Massachusetts”, 0.15%
•
Propane, 0.44%
Compliance:
•
GPTC for 49 CFR Subpart L, 192.625
•
ASTM D6273
Safety Certifications:
•
Class 1, Division 2, Group D, T4
•
USA
–
47 CFR Part 15; Class A
•
Canada
–
Industry Canada ICES-003 Issue 5, 2012
•
Class A European Union
–
EMC Directive 2004/108/EC
Utilizing EN613261-1:2006 for Portable Test.
•
Measurement Equipment Supplied with NRTL Listed cUL/UL/CE marked power supply/cord set.
•
Enclosure with latched lid compliant for Type 3R testing, UL50/CSA 22.2 No. 94.1, 12
th
edition
Battery Pack & Run-Time:
•
Internal rechargeable Li Ion, 3 weeks typical run time
Battery Charger/Power Supply:
•
External, in-line, 110-240 VAC - 1.6A, 50/60 Hz, 18 VDC output
Typical Connectivity:
•
USB 2 and Bluetooth
Recording Media:
•
SDHC memory card; not accessible.
Recorded Data:
•
All readings with GNSS location, UTC time and date, instrument status and breadcrumb trail.
Inlet Supply Pressure:
•
7” water column typical, 4 PSIg. maximum
Instrument Size:
•
14” x 12” x 5” (35 cm x 30 cm x 8 cm)
Instrument Weight:
•
9.5 lbs. (4.3 kg)
Operating Temperature & Humidity Range:
•
**0°F to 122°F (-18 to 50°C) & 5% - 95% RH, non-condensing
Elevation Range:
•
Sea level to 10,000 ft. (3,048 meters)