ENVIRONMENT. LIKEWISE, ALLOW THE ODORATOR 2 TO PURGE FOR AT LEAST ONE 
MINUTE AFTER A REFERENCE CGI ALSO INDICATES  SAFE ENVIRONMENT.  
 
DO NOT PERFORM TESTS IN CLOSED OR CONFINED SPACES FOR PERSONNEL SAFETY. 
 
PERFORM ALL MAINTENANCE IN A LOCATION KNOWN TO BE NON-HAZARDOUS. 
 
TO REDUCE THE RISK OF IGNITION OF A FLAMMABLE OR EXPLOSIVE ATMOSPHERE, THE 
BATTERY PACK MUST BE CHANGED OR CHARGED ONLY IN A LOCATION KNOWN TO BE NON-
HAZARDOUS. 
 
NO ATTEMPT SHOULD BE MADE TO REPAIR THE INSTRUMENT BY THE OPERATOR.  SHOULD THE 
INSTRUMENT NOT WORK PROPERLY OR INDICATE AN ERROR OR WARNING, REFER TO THE 
TROUBLESHOOTING SECTION OF THIS MANUAL. DO NOT OPERATE THE INSTRUMENT TO SNIFF 
HAZARDOUS GAS IF INS

TRUMENT INDICATES ‘ERRxx’ (error). 

 
SUBSTITUTION OF COMPONENTS MAY IMPAIR SAFETY.  NO OPERATOR SERVICEABLE 
COMPONENTS ARE CONTAINED WITHIN THE INSTRUMENT. 
 
ONLY USE BATTERY PACK HPN 101311-0. ONLY USE THE POWER SUPPLY AND CORDS 
PROVIDED WITH THE INSTRUMENT TO CHARGE THE BATTERY. REPLACEMENT OF CORDS BY 
INADEQUATELY RATED CORDS CAN RESULT IN UNSAFE OPERATION. USING A DIFFERENT 
POWER SUPPLY FOR CHARGING THE INSTRUMENT MAY ALSO RESULT IN DAMAGE TO THE 
BATTERY AND THE INSTRUMENT.                      

                                                                                           

TO REDUCE THE RISK OF IGNITION OF A FLAMMABLE OR EXPLOSIVE ATMOSPHERE, ANY CABLE 
(POWER or USB) MUST ONLY BE CONNECTED IN A LOCATION KNOWN TO BE NON-HAZARDOUS. 
 
DO NOT OBSTRUCT OR BLOCK THE  INTAKE OR EXHAUST PORTS. 
 

CAUTION: 

TESTS SHOULD NOT BE PERFORMED IN WINDY CONDITIONS, RAIN OR SNOW.  THE ODORATOR2 
LID SHOULD BE CLOSED AND LATCHED WHEN NOT IN USE.  

 

CAUTION: 

Do not store the gas sample hose in the case.  The gas sample 

hose must “breathe” in fresh air to 

lengthen its useful life and not contaminate the instrument.  A mesh bag attached to the carrying 
handle is included and recommended to be used for storage.  
 

CAUTION: 

Because  of  inherent limitations,  liquid  crystal  displays  should  not  be  subjected  to  extremes 

of  temperature  or  humidity.  I f   the  instrument  is  exposed  to a temperature  below  - 2 0

o

F  

( - 2 9

o

C )   or  above 158

o

F  ( 70

o

C),  the  liquid  crystal display  may temporarily cease to function 

properly and  in  some  cases,  permanent damage  may result.    I t  is therefore  recommended 
that the  instrument  not be subjected to extreme conditions such as a  closed vehicle in direct 
sunlight or continuous  sub-freezing temperatures. 
 
The battery pack contains thermal protection and will internally disconnect at temperatures 

above 122

o

F (50

o

C). Do not charge the battery pack at temperatures above 104

o

F (40

o

C). 

 

WARNING: 

Do not expose the battery pack to temperatures above 158

o

F  ( 70

o

C). 

Summary of Contents for Odorator 2

Page 1: ...ODORATOR 2TM Operator s Manual All Models...

Page 2: ...onsent of Heath Consultants Incorporated Heath Consultants Incorporated operates under a continual product improvement program and reserves the right to make improvements and or changes without prior...

Page 3: ...Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Tel 713 844 1300 www heathus com ODORATOR 2 Operator s Manual Models 1 00 Methane 0 50 Methane 0 15 Methane 0 44 Propane...

Page 4: ...ocedure 7 Bluetooth 10 ODORATOR 2 Operator Controls and Connectors 10 Figure 1 ODORATOR 2 Top Panel Layout 10 Figure 2 ODORATOR 2 Rear Case View 11 Battery Charging 11 Battery Pack Replacement 12 CHAP...

Page 5: ...to show the actual breadcrumb trail used The electronics and the speed of the blower are calibrated so that the concentration of the gas air sample at the exhaust port agrees with the LCD reading at 2...

Page 6: ...S MORE THAN FOUR PSIG COULD RUPTURE THE LOW PRESSURE REGULATOR DIAPHRAM VENT THE GAS OUT OF THE INSTRUMENTAND CAUSE INSTRUMENTFAILURE THE RECOMMENDED INLET SUPPLY PRESSURE IS 7 WATER COLUMN WHEN OPERA...

Page 7: ...THE RISK OF IGNITION OF A FLAMMABLE OR EXPLOSIVE ATMOSPHERE ANY CABLE POWER or USB MUST ONLY BE CONNECTED IN A LOCATION KNOWN TO BE NON HAZARDOUS DO NOT OBSTRUCT OR BLOCK THE INTAKE OR EXHAUST PORTS...

Page 8: ...nt for Type 3R testing UL50 CSA 22 2 No 94 1 12th edition Battery Pack Run Time Internal rechargeable Li Ion 3 weeks typical run time Battery Charger Power Supply External in line 110 240 VAC 1 6A 50...

Page 9: ...of affecting their sense of smell Proper use of the ODORATOR 2 requires an operator with a normal sense of smell List of Contents The following items are included with the ODORATOR 2 1 ODORATOR 2 ins...

Page 10: ...ibration 12 CAL OK 13 A live reading display in Gas unit The actual battery capacity will be shown on the bar graph on the left side of the display The turn on sequence will generally take 20 30 secon...

Page 11: ...ed and the ODORATOR 2 turned OFF Odor Threshold Level and Relative Odor Intensity Tests Procedure 1 Prior to attaching the sample hose sniff the sample hose and verify no odor is detected If odor is d...

Page 12: ...ten only 7 Wait about 30 seconds and then position the nose approximately 3 4 inch 20 mm above the exhaust port and sniff the exhaust The exhaust must be un odorized If odorant is detected the ODORATO...

Page 13: ...shown on the display The display count will change by one for each or key press and alternate between ROI and the count value For example after 5 key presses 5 0 80 would indicate a rating of 5 relati...

Page 14: ...ndle is included for sample hose and fittings storage Bluetooth NOTE Bluetooth hardware is installed and configured but connectivity is not supported A future firmware and OdorSeer OdorSeer Remote rel...

Page 15: ...leep The ODORATOR 2 must be recharged in this case prior to use NOTE In order to obtain full battery capacity charge the battery pack when the ambient temperature is above 50 F 10 C and below 85 oF 30...

Page 16: ...the top of the cover slightly out then up to remove the cover 5 Squeeze the cable connector s lock to disengage and unplug the battery from its extension cable 6 Plug in the new battery pack The inst...

Page 17: ...forms on pages 16 and 17 are provided to document the Periodic Tests as a courtesy only Your Company s procedures will define how records are kept and in what format Calibration For regulatory complia...

Page 18: ...always detected Contaminated sample hose or flow system Change tubing RMA The RMA process may be found on page 18 of this manual Parts List The following list specifies ODORATOR 2 parts and accessori...

Page 19: ...or this test may be found on page 13 of this manual The forms on pages 16 and 17 are provided for your convenience They should remain in the manual and be kept in a safe location as a permanent record...

Page 20: ...16 Periodic Test Records Test Date Results Action Operator Name...

Page 21: ...17 Periodic Test Records Test Date Results Action Operator Name...

Page 22: ...er than a Heath warranty repair location Batteries and damage from battery leakage and all expendable items such as filters and tubing are excluded from this warranty Heath s responsibility is express...

Page 23: ...air form requests information such as complete shipping and billing addresses instrument or product name model number and serial numbers Also included will be a brief description of the problem you ar...

Page 24: ...061 Model Odorator 2 Has been demonstrated to be in compliance with the European EMC directive 2004 108 EC FCC 47 CFR Part 15 and Industry Canada ICES 003 and is in accordance with the following stand...

Page 25: ...Park Way Monongahela PA 15063 Phone 724 242 3145 Fax 724 872 3206 Southwest Region Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Phone 713 844 1300 Fax 713 844 1309 Western Region H...

Page 26: ...22...

Page 27: ...__________________________________________________________________ ___________________________________________________________________________ _________________________________________________________...

Page 28: ...Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Tel 713 844 1300 www heathus com...

Reviews: