Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. K • 12/07
25
The factory supplied non-combustible board spans the
distance from the top of the fi replace to the center of the
framing header. This board must be used. See fi gure
7.8.
NAILING TABS
(BOTH SIDES)
Figure 7.6
Remove the insulation from the outer vent pipe.
For rear venting there is no insulation in the outer vent pipe.
Replace the top heat shield.
Figure 7.7
To attach the fi rst section of vent pipe, make
sure to use the fi berglass gasket in the manual bag to seal
between the fi rst vent component and the outer fi replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.
Secure the fi rst section of venting to the fi replace by screw-
ing through the two tabs bent up out of the vent hole in the
heat shield.
Note:
Once the vent cap has been removed,
it cannot be reattached.
C. Securing and Leveling the Appliance
The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.9). Nailing tabs are pro-
vided to secure the appliance to the framing members.
• Venting - refer to Vent Clearances and Framing (Section
6) for hole location.
• Place the appliance into position.
• Level appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use
wood shims.
• Bend out nailing tabs on each side.
• Keep nailing tabs fl ush with the framing.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Figure 7.9 Proper Positioning,
Leveling and Securing of a Appliance
WARNING
WARNING
Fire Risk.
• ALWAYS maintain specifi ed
clearances around the appliance.
• Do NOT notch into the framing around the appliance spacers.
Failure to keep insulation, framing or other material away
from the appliance may cause fi re.
Fire Risk.
•
Prevent contact with sagging, loose insulation.
•
Do NOT install against combustible materials
Figure 7.8 Non-combustible Board
B. Installing the Non-combustible Board
such as exposed insulation, plastic and insulation backer.
NOTE:
Once appliance is setup for top or rear venting,
it CANNOT be changed at a later time.
HEADER
HEADER