Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. K • 12/07
21
4. Rear Vent - Vertical Termination - (continued)
Three Elbows
Figure 5.19
Three Elbows
Figure 5.20
H
1
H
2
H
3
V
1
Minimum
H
1
+ H
2
+ H
3
Maximum
*
*
*
8 ft.
2.4 m
6 ft.
1.8 m
*
*
*
9 ft.
2.7 m
7 ft.
2.1 m
*
*
*
10 ft.
3.1 m
8 ft.
2.4 m
*
*
*
10 ft.
3.1 m
8 ft.
2.4 m
V
1
+ H
1
+ H
2
+ H
3
= 40 ft. (12.2 m) Maximum
*No specifi c restrictions on this value EXCEPT
V
1
+ H
1
+ H
2
+ H
3
cannot exceed 40 ft. (12.2m) Maximum
H
1
+ H
2
+ H
3
= 8 ft. (2.4 m) Maximum
INSTALLED
HORIZONTALLY
H
2
H
3
H
1
V
1
H
1
V
1
H
2
V
2
H
1
Maximum
V
1
Minimum
H
2
H
1
+ H
2
Maximum
2 ft.
610 mm
6 in.
152 mm
2 ft.
610 mm
4 ft.
1.2 m
3 ft.
914 mm
1 ft.
305 mm
4 ft.
1.2 m
7 ft.
2.1 m
5 ft.
1.5 m
2 ft.
610 mm
6 ft.
1.8 m
11 ft.
3.4 m
7 ft.
2.1 m
3 ft.
914 mm
8 ft.
2.4 m
15 ft.
4.6 m
8 ft
2.4 m
4 ft.
1.2 m
10 ft.
3.1 m
18 ft.
5.5 m
H
1
Max. = 8 ft (2.4 m) V
1
+ V
2
+ H
1
+ H
2
= 40 ft (12.2 m) Maximum
H
1
+ H
2
= 20 ft (6.1 m) Maximum