Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. K • 12/07
43
Í
Í
Í
Í
Í
Í
Í
Í
Í
STEP 2.
Place the metal grate on top of the burner.
Position the legs of the grate into the forward set
of indentations in the burner top, sliding the grate
forward. See Figure 12.8.
Log Set Assembly: LOGS-6000GLX
LOGS-6000GLXLP
STEP 1.
CAUTION:
Logs are fragile! Carefully remove
the logs, grate and supporting cardboard from
the inside of the fi replace See Figure 12.7.
G. Positioning the Logs
If the gas logs have been factory installed they
should not need to be positioned. If the logs have
been packaged separately, refer to the following
instructions.
Figure 12.8
Figure 12.10 Top View
2101-910
1
1
2
2
3
3
4
4
5
5
STEP 3.
Log #1 NG (SRV2101-085):
Log #1 LP (SRV2101-087):
Log #1 is the left burning log. The air shutter in
the end of the burner tube goes over the left brass
orifi ce located behind the main burner. The left
end of the log goes tight against the left refractory
wall. See Figures 12.9 and 12.10.
1
1
Figure 12.7
1
1
Figure 12.9 Front View
6
6
7
7
HUMP
HUMP