Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. K • 12/07
4
NOTE:
This installation must conform with local codes. In the
absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A.
and the
CAN/CGA B149 Installation Codes
in Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
Listing and Code Approvals
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above
a 2000 foot elevation in the U.S.A., or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating
value of the gas has been reduced, these rules do not
apply. To identify the proper orifi ce size, check with the
local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
B. BTU Specifi cations
1
MODELS: 6000GLX-IPI-R, 6000GLX-IPI-S,
6000GLX-IPILP-R, 6000GLX-IPILP-S
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88-2000•CSA2.33-M98•UL307B
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for Use
at High Altitudes”.
Heat & Glo Quality Systems
registered by SGS ICS
Models
U.S. (0-2000 FT) or Canada (2000-4500 FT)
Maximum
Input
BTUH
Minimum
Input
BTUH
Orifi ce
Size
(DMS)
6000GLX-IPI-R (NG)
6000GLX-IPI-S (NG)
US
40,000
18,700
39
53 (2)
CANADA
36,000
16,830
40
54 (2)
6000GLX-IPILP-R
6000GLX-IPILP-S
US
36,000
16,500
54
68 (2)
CANADA
32,400
14,850
55
69 (2)
A. Appliance Certifi cation
D. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing
ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750
o
C,
shall be considered
non-combustible materials.
E. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can
ignite and burn, whether fl ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.