Installing  the  Fireplace 

(continued)

STANDING PILOT

(VEILLEUSE)

DSI IGNITION

(ALLUMAGE DSI)

Figure 10. Gas Controls Systems

Step 7

The  Gas  Supply  Line

NOTE: Have the gas supply line installed in accordance

with  local  building  codes  by  a  qualified  installer

approved and/or licensed as required by the locality.
NOTE: Before the first firing of the fireplace, the gas

supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size

the  gas  supply  line  leading  to  the  1/2  inch

(13 mm) hook-up at the unit.

This  gas  fireplace  is  designed  to  accept  a  1/2  inch

(13 mm) gas supply line. To install the gas supply line:
• A listed (and State of Massachusetts approved) 1/2 inch

(13mm) tee-handle manual shut-off valve and a listed

flexible gas connector are connected to the 1/2 inch

(13mm) inlet of the control valve. 

NOTE:

 If substituting

for these components, please consult local codes for

compliance.

• The gas line may be run from either side of the fireplace

provided the hole in the outer wrap does not exceed 2

inches in diameter and it does not penetrate the airtight

firebox.

• The gap between the supply piping and gas access hole

can be plugged with non-combustible insulation to pre-

vent cold air infiltration.

• Locate the gas line access hole in the outer casing of

the fireplace.

• Open the fireplace lower grille, insert the gas supply

line through the gas line hole, and connect it to the

shut-off valve.

• When attaching the pipe, support the control so that

the lines are not bent or torn.

• After the gas line installation is complete, use a soap

solution to carefully check all gas connections for leaks.

WARNING: DO NOT USE AN OPEN FLAME TO

CHECK FOR GAS LEAKS

.

!

Figure 10. Systèmes de commande de gaz

Étape  7

Conduit à gaz

REMARQUE  :  Le  conduit  gaz  doit  être  installé

conformément  aux  codes  de  construction  locaux.

L'installation  doit  être  effectuée  par  un  technicien

qualifié  et/ou  muni  d'une  licence  de  manière  à  re-

specter les règlements municipaux.
REMARQUE : Avant d’allumer le foyer pour la première

fois, toutes les bulles d’air doivent être évacuées du

conduit à gaz.
REMARQUE :  Consultez  les  codes  de  construction

locaux  pour  choisir  correctement  le  diamètre  du

conduit à gaz s’acheminant vers le raccord de 13 mm

du foyer.

Ce foyer à gaz est conçu pour accepter un conduit à gaz

de 13 mm. Pour installer le conduit à gaz :
• Un robinet manuel à poignée en T de 13 mm (1/2 po)

homologué (et approuvé par l'État du Massachusetts)

et un tuyau à gaz flexible homologué sont branchés à

l'orifice d'admission de la valve de commande de 13 mm

(1/2 po). REMARQUE : Veuillez consulter les codes

locaux  pour  vous  assurer  que  les  éléments  de

remplacement sont réglementaires.

• Le conduit à gaz peut arriver d’un côté ou de l’autre du

foyer, à condition que l’orifice pratiqué dans l’extérieur

du foyer ne dépasse pas 50,8 mm de diamètre et que

le conduit ne pénètre pas dans le foyer hermétique.

• L’écart entre la tuyauterie d’approvisionnement et l’orifice

d’accès du conduit à gaz peut être bouché à l’aide d’isolant

non combustible pour empêcher l’infiltration d’air froid.

• Repérez l’orifice d’accès du conduit à gaz dans la paroi

extérieure du foyer.

• Ouvrez la grille inférieure du foyer, insérez le conduit à

gaz dans l’orifice d’accès du conduit à gaz et branchez-

le au robinet.

• Pour brancher le tuyau, soutenez la commande afin que

les conduits ne soient pas tordus ou rompus.

• Une fois l’installation du conduit à gaz terminée, utilisez

une solution savonneuse pour détecter des fuites sur

tous les raccords de gaz.

AVERTISSEMENT :  N’UTILISEZ  PAS  DE

FLAMME NUE POUR DÉTECTER DES FUITES

DE GAZ

.

Installation du foyer 

(suite)

Summary of Contents for SL-550TV

Page 1: ...api ce leb timentoulazone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service de...

Page 2: ...mencer l installation Si ces instructions d installation ne sont pas suivies un risque d incendie pourrait en r sulter et la garantie sera annul e Avant l allumage initial LISEZ la section du Guide de...

Page 3: ...des syst mes d vacuation d crits dans la section intitul e Installation du foyer dans le Guide d installation AUCUN AUTRE syst me ou l ment d vacuation NE PEUT TRE UTILIS Cet appareil gaz et ce syst m...

Page 4: ...et mises en garde 2 Liste des pi ces de rechange 5 Section 1 Homologations et codes 11 Homologations et codes 11 Homologation de l appareil 11 Codes d installation 11 Installation haute altitude 12 S...

Page 5: ...d les de foyer Heat N Glo dont il est question dans ce Guide d installation ont t test s conform ment aux normes d homologation et ont t approuv s par les laboratoires comp tents NORME D HOMOLOGATION...

Page 6: ...mining the proper orifice for your location Approvals and Codes continued Installation haute altitude Les foyers homologu s U L ont t test s et approuv s pour fonctionner entre 0 et 610 m tres d altit...

Page 7: ...tation des foyers gaz Heat N Glo Les foyers gaz syst me d vacuation de type B Heat N Glo sont con us pour expulser tous les gaz de combustion en dehors de l difice Les informations contenues dans ce G...

Page 8: ...finition Si vous d sirez installer des accessoires facultatifs dispositifs tels qu un ventilateur un interrupteur mural ou une commande distance Si le foyer doit tre install sur du tapis du carrelage...

Page 9: ...TRIQUE 8 203 mm VENT STARTING COLLAR COLLET DE RACCORD DU SYST ME D VACUATION 30 3 4 781 mm 8 1 8 207 mm ACC S DU CONDUIT GAZ LINE ACCESS GAS ELECTRICAL ACCESS HOOD HOTTE STANDOFFS ENTRETOISES VENT CO...

Page 10: ...TRIQUE GAS CONTROLS COMMANDES DE GAZ GRILLE INF RIEURE RATING PLATE LABELS GAS ACCESS PORTE DE GARNITURE TRIM DOOR HOTTE HOOD ENTRETOISES SUP RIEURES TOP STANDOFFS 41 3 4 1061 mm 2 1 4 57 mm 5 3 8 138...

Page 11: ...Arri re Sides 1 2 13 C t s Top SL 550 1 1 2 38 Dessus SL 550 SL 750 3 1 4 83 SL 750 SL 950 3 1 4 83 SL 950 Ceiling 31 787 Plafond Inches mm Figure 4 Dimensionsetsp cifications de d gagement D gagemen...

Page 12: ...rbon monoxide situation in the house tape 3 Air de compensation en cas de pression n gative dans la pi ce Avertissement en cas de pression n gative dans la pi ce En cas de pression n gative un foyer s...

Page 13: ...ative Cet appareil est con u de fa on pouvoir accepter une prise d air ext rieur Gr ce l air de com pensation ext rieur la quantit d air de la pi ce utilis e pour la combustion est r duite Il est cons...

Page 14: ...du syst me d vacuation A Homologation du syst me d vacuation Les mod les SL 550TV et SL 750TV sont approuv s pour raccordement un conduit d vacuation de type B de 127 mm de diam tre Le mod le SL 950T...

Page 15: ...vacuation L apparence des flammes et des braises peut varier selon le type de combustible br l et la configuration du syt me d vacuation B l ments du syst me Configuration du syst me d vacuation PROPO...

Page 16: ...ENT LA HAUTEUR MINIMALE DE LA CHEMI N E ET OU DU CONDUIT D VACUATIONAU DESSUSDUTOIT CESHAUTEURSMINIMALES SONT N CESSAIRES POUR DES RAISONS DE S CURIT LA FIGURE 8 ET LE TABLEAU INDIQUENT LES HAUTEURS M...

Page 17: ...t me d allumage par tincelle directe DSI Le syst me DSI comprend une valve de commande 120 V un module lectronique et un allumeur tincelle d tecteur de flamme AVERTISSEMENT SUR UN SYST ME DSI UN COURA...

Page 18: ...re 10 Syst mes de commande de gaz tape 7 Conduit gaz REMARQUE Le conduit gaz doit tre install conform ment aux codes de construction locaux L installation doit tre effectu e par un technicien qualifi...

Page 19: ...etween the pipe and the outer casing Figure 11 Gas Supply Line Step 8 Gas Pressure Requirements Pression Gaz naturel Propane Pression minimale 127 mm 279 mm d approvisionnement CE CE Pression maximale...

Page 20: ...lleuse tape 9 Filage lectrique du foyer Installation du foyer suite REMARQUE Le filage lectrique doit tre effectu par un lectricien agr Attention D branchez les commandes distance si vous vous absente...

Page 21: ...nstallation du foyer suite Filage de l allumage par tincelle directe DSI Sp cifications de l appareil Sur cet appareil un courant lectrique de 110 120 VCAdoit tre branch la bo te de d rivation incluse...

Page 22: ...MAL ET DANGEREUX V RIFIEZ LE BON FONCTIONNEMENT DE L APPAREIL APR S CHAQUE SERVICE Figure 14 Sch ma de filage de l allumage par tincelle directe DSI BLACK NOIR FLAME SENSOR SPARKER D TECTEUR DE FLAMME...

Page 23: ...f Combus tibles above Fireplace Installation du foyer suite tape 10 Finition Le sch ma suivant indique le d gagement vertical minimal et les dimensions horizontales maximales correspondantes des habil...

Page 24: ...r suite ATTENTION SI LES JOINTS ENTRE LES MURS FINIS ET L ENTOURAGE DE FOYER DESSUS ET C T S SONTSCELL S UNPRODUITDESCELLAGEPOUVANT R SISTER 149 C MINIMUM DOIT TRE UTILIS IL N EST PAS N CESSAIRE DE SC...

Page 25: ...ettez le au rebut Abaissez la grille sur la base r fractaire Figure 17 Positioning the Logs If the gas logs have been factory installed they should not need to be positioned If the logs have been pack...

Page 26: ...rre Figure 19 Placement of the Ember Material IT IS STRONGLYRECOMMEND ED THAT TRIM DOORS WITH OPTIONAL MESH SCREENS BE INSTALLEDONPROPANEMOD ELS Figure 19 Mise en place des braises IL EST FORTEMENT CO...

Page 27: ...op rations suivantes Retirez tous les papiers et tous les documents qui pourraient se trouver sous le foyer Revisez les consignes de s curit et les mises en garde Lisez la section Consignes de s curit...

Page 28: ...yer Entretien du foyer Bien que la fr quence de l entretien et des services de votre foyer d pende de son utilisation et du type d installation il est conseill de demander un technicien de service qua...

Page 29: ...4 5 000 162 5 016 609 5 076 254 5 191 877 5 218 953 5 328 356 5 429 495 5 452 708 5 542 407 5 613 487 Australie 543790 586383 Canada 1 123 296 1 297 746 2 195 264 Mexique 97 0457 Nouvelle Z lande 2002...

Reviews: