47
Heat & Glo •
TRUE-36, TRUE-42, TRUE-50 • 2282-900 Rev. i •
4/13
13
13
Finishing
A. Finishing Templates
Two side
fi
nishing templates and one top
fi
nishing template
are supplied with the appliance. They are fastened to the
top surround.
INSIDE FIT Method: The
fi
nishing template pieces are
required for installations that require more than one inch
thick
fi
nishing materials to be installed over the face of the
factory-supplied 1/2 inch non-combustible board. Refer
to section 13.E for more information.
OVERLAP Method: The supplied templates are not
required for
fi
nishing materials less than one inch thick.
The required decorative front will overlap
fi
nish materials
less than one inch thick. Refer to section 13.E for more
information.
Note:
For Arch Door applications with
fi
nish material
greater than one inch thick, an Arch Template Kit is
available. Contact your dealer to order the arch template
kit.
Template Installation Instruction
1. Bend the left and right side templates for the appropriate
door type using Figure 13.2 as a reference.
2. Locate the four threaded inserts on the inside edge of
the
fi
replace and secure the side templates with the
Phillips screws provided. See Figure 13.3.
3. Bend the top template as shown in Figure 13.1 and
secure with the two screws provided. The bend will
have two opposing 90 degree bends, similar to the
bends on the side templates.
4. Remove all template components once
fi
nishing
materials are secured.
3/4 IN.
Figure 13.2 Left and Right Side Finishing Template Bends
TOP FINISHING
TEMPLATE
SIDE FINISHING
TEMPLATES
Figure 13.3 Top and Side Finishing Template Locations
Note:
For Firesceen Fronts (denoted with “FS”), a thin
layer of mortar may be applied over the visible non-
combustible board between
fi
nishing material and the
fi
replace opening.
Figure 13.1 Top Finishing Template Bend
1-1/4 IN.
TAB