23
Heat & Glo •
TRUE-36, TRUE-42, TRUE-50 • 2282-900 Rev. i •
4/13
NON-COMBUSTIBLE
BOARD
HEARTH CLEARANCE
BRACKET
NON-COMBUSTIBLE
HEARTH EXTENSION
1 IN. THICK MAX.
WOOD OR OTHER COMBUSTIBLE
FLOOR OR PLATFORM
E. Hearth Extension
WARNING! Risk of Fire!
Non-combustible hearth exten-
sion may be required when appliance is installed on com-
bustible surface.
• Hearth extension must be non-combustible and
serves to protect combustible
fl
oors in front of appli-
ance. See Figure 5.11.
• The base of the
fi
replace may sit on a combustible sur-
face. See Figure 5.11. The area in front of the appli-
ance must be protected by a non-combustible hearth
extension, unless the appliance is raised a minimum
of three inches above the combustible
fl
oor or hearth.
See Figure 5.11 and Figure 5.12.
Figure 5.10 Non-Combustible Hearth Extension Dimensions
A
B
NON-COMBUSTIBLE
MODEL
A
B
in.
mm
in.
mm
TRUE-36
12
305
57-1/4
1454
TRUE-42
12
305
63-5/16
1608
TRUE-50
12
305
71-5/16
1811
Figure 5.11 Appliance Installed on Combustible Surface
Non-Combustible Hearth Extension REQUIRED.
NOTICE: DO NOT
install a hearth that is greater than
one inch thick. Hearth will interfere with installation of
glass assembly. Total hearth height must not exceed one
inch from bottom of appliance when appliance is installed
directly on
fl
oor (including mortar, backer material, etc.)
If a hearth greater than one inch in thickness is desired,
the appliance must be raised by the equivalent height
to ensure that the hearth extension does not interfere
with the installation of the glass assembly required for
fi
replace operation. See Figure 5.11.
NON-COMBUSTIBLE
BOARD
HEARTH CLEARANCE
BRACKET
WOOD OR OTHER COMBUSTIBLE
FLOOR OR PLATFORM
4 IN.
3 IN. MIN.
BOTTOM OF
FIREPLACE
1/2 IN. MAX.
THICKNESS
COMBUSTIBLE
BUILDING
MATERIAL
Figure 5.12 Appliance Raised a Minimum of 3 Inches Above
Combustible Surface.