Heat & Glo • SL-5F-IFT, SL-7F-IFT Installation Manual • 2638-980 Rev. H • 6/22
70
DVP-HPC1
DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8)
DVP-HPC2
DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2)
DVP-TRAP1
DVP-TRAP2
DVP-TRAPK2
DVP-TRAPK1
DVP-TRAP
Horizontal Termination Cap
15-1/8 in.
(384 mm)
12 in.
(305 mm)
8 in.
(203 mm)
Max
Effective
Length
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).
The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick.
If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
Heat
Shield
*5 in.
(127 mm)
* Center of the horizontal vent pipe to
the vertical measuring surface.
A. Vent Components Diagrams (
continued
)
Figure 12.2 DVP Vent Components
Term Cap
Minimum
Effective Length
Maximum
Effective Length
Trap1
3-1/8 in.
4-5/8 in.
79 mm
117 mm
Trap2
5-3/8 in.
9-3/8 in.
137 mm
238 mm