Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Component Tray
The electrical components are installed on the component
tray. If it becomes necessary to remove the components,
use the information in Figure 8.2 to remove them and
reinstall them correctly on the component tray.
The IFT-ECM is held in position by two placement tabs
(front and rear) on the component tray. To remove the IFT-
ECM, bend the front or rear placement tab back slightly
and tip the IFT-ECM to disengage it from the placement
tabs. To reinstall the IFT-ECM on the component tray,
engage the front placement tab first.
Figure 8.2 Electrical Component Tray
IFT-ECM FRONT
PLACEMENT TAB
IFT-ECM REAR
PLACEMENT TAB