9
Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls. See Figure
3.3 and Figure 3.4.
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traf
fi
c and away from furniture and draperies.
NOTICE:
Illustrations re
fl
ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
1 IN.
45°
1 IN.
A
E
A
B
C
TOP VENT
ONE 90° ELBOW
ALCOVE
INSTALLATION
B
TOP VENT
ONE 90° ELBOW
B
F
D
Figure 3.3 Appliance Locations RED40
A
B
C
D
E
F
Inches
60-3/8
50
85-3/8
See Section D.
Figure 5.6 & 5.7
24-1/8
18-3/4
Millimeters
1533
1270
2168
613
476
It is important to follow the framing and
fi
nishing instruc-
tions step by step to ensure proper placement of
fi
replace
in the surrounding framing/
fi
nishing materials. For addi-
tional information and considerations for the active con-
vection technology in regards to appliance location and
framing, see Section 6.
Note:
Consider installation of the active con-
vection blower when determining appliance
location. See Section 6.C for more detailed
information.