B. Wiring Requirements
Intelli
fi
re Ignition System Wiring
• Wire the appliance junction box to 110/120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.5, Intelli
fi
re Pilot Ignition (IPI) Wiring
Diagram.
• This appliance is equipped with an Intelli
fi
re control valve
which operates on a 3 volt system.
• Plug the 3-volt AC transformer into the appliance junction
box to supply power to the appliance.
Figure 8.2. Valve Cavity (Lower Access Panel Removed)
THERMODISC
VALVE
MODULE
Figure 8.3. Valve Cavity
JUNCTION
BOX
OPTIONAL
REMOTE
CONTROL
MODULE
FAN
INSTALLED ON
RIGHT
VALVE
FAN
INSTALLED ON
LEFT
JUNCTION
BOX
VALVE
CONTROL
MODULE
OPTIONAL
REMOTE
Figure 8.4. Controls Location Diagram
FAN ASSEMBLY
FAN ASSEMBLY
JUNCTION BOX
JUNCTION BOX
Optional Accessories Requirements
• This appliance ships standard with a wall switch and may
use a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Optional Remote Control Receiver
The junction box, control module, light controller and
wall switch receiver can be accessed thru the air space
between the
fi
rebox front and the lower-front
fi
nishing
cover panel. The decorative front and glass assembly
must be removed to access these components. See
Figure 8.2.
Note:
If the fan is moved from one side to the other,
the junction box must also move. See appropriate
con
fi
guration in relation to the valve in Figure 8.4. The
valve does not move.