Heat & Glo • Bravo • 704-902 Rev. J • 10/10
24
H
1
V
1
Figure 7.3
Figure 7.4
One Elbow
Two Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Top Vent - Horizontal Termination
E. Vent Diagrams
Note:
When installing the TAOS surround and
venting with one elbow, a straight section of
venting (30 in. minimum)
MUST
be attached
directly to starting collars on unit.
Note:
V
1
MUST
be a minimum
of 3 feet unless using the TAOS
surround. For TAOS surround, V
1
minimum
MUST
be 30 in.
V
1
Minimum
H
1
Maximum
3 ft.
0.9 m
2 ft.
0.6 m
4 ft.
1.2 m
4 ft.
1.2 m
5 ft.
1.5 m
6 ft.
1.8 m
12 ft.
3.7m
20 ft.
6.1 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 20 ft. (6.1 m) Maximum
Note:
The fi rst elbow used
MUST
always be
DVP90ST.
Note:
The fi rst elbow used
MUST
always be DVP90ST.
V
1
Minimum
H
1
+ H
2
Maximum
3 ft.
0.9 m
2 ft.
0.6 m
4 ft.
1.2 m
4 ft.
1.2 m
5 ft.
1.5 m
6 ft.
1.8 m
12 ft.
3.7 m
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.1 m) Maximum