A. Typical Appliance System
NOTICE:
Illustrations and photos re
fl
ect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual
Figure 4.1 Typical System
CEILING FIRESTOP
ON FLOOR OF ATTIC
(SECTION 8.C)
VERTICAL TERMINATION CAP
(SECTION 10.G)
VENT PIPE PENETRATES ROOF
PREFERABLY WITHOUT AFFECTING
ROOF RAFTERS (SECTION 8.C)
FRAMING HEADED OFF
IN CEILING JOISTS
(SECTION 8.C)
GAS LINE
(SECTION 11)
MANTEL AND
MANTEL LEG
(SECTION 5.D)
CLEAR SPACE (SECTION 2.C)
VENT PIPE (SECTIONS 7 and 8)
WALL SWITCH
(SECTION 12.C)
STORM COLLAR
(SECTION 10.F)
NON-COMBUSTIBLE ROOF FLASHING
MAINTAINS MINIMUM CLEARANCE
AROUND PIPE (SECTION 10.E)
FRAMING/HEADER
(SECTION 5.C)
ATTIC INSULATION SHIELD (NOT
SHOWN) MUST BE USED HERE
TO KEEP INSULATION AWAY
FROM VENT PIPE IF ATTIC IS
INSULATED (SECTION 8.D)
Note:
Dual venting configurations
ARE NOT
allowed. Appliance
MUST
be vented
EITHER
vertically
OR
horizontally.