Heat & Glo • Bravo • 704-902 Rev. J • 10/10
42
C. Finishing Styles
This model has multiple installation and fi nishing options.
The following section describe fi ve basic installations.
Figure 13.4 Flush Wall Installation
• Appliance is installed using framing dimensions found
in Figure 3.2.
• Do not use nailing tabs provided on appliance sides for
Option A.
• Nailing tabs are attached to the top of the appliance.
Install nailing tabs using screws on upper appliance
sides (see Figure 13.3).
• This places appliance back 1/2 inch from framing studs
such that drywall or other material can be brought directly
across non-combustible board up to fi nish edge trim.
WARNING! Risk of Fire!
1/2 inch non-combustible board
installed on front face of
fi
replace MUST remain if using
combustible
fi
nishing materials.
• A cardboard template is printed on appliance shipping
carton and may be used to help cut drywall or other
fi nishing materials. Simply cut along line and use it as a
template.
• Drywall or other fi nishing materials may be fi nished all the
way up to the fi nishing edge trim or appliance front face,
but MUST NOT extend inside of fi nishing edge trim.
NOTICE:
Finishing materials cut inside the provided
template will cause the door not to
fi
t.
• Finishing materials may be fastened or secured to
appliance below the glass/front opening.
OPTION A: Flush Wall Finish
Kiva-style fi nished in a straight wall (see Figure 13.4).
Figure 13.5 Kiva-style Arch Installation
• Framing depth increases from that shown in Figure 3.2,
(Dimension C). Dimension C will vary depending on the
depth of the desired kiva-style arch (see Figure 13.5).
• Once depth of desired kiva-style arch is determined
(minimum of 3 in. - 3/32 in. and maximum 5 in.), add that
to Dimension C from Figure 5.2. Level, set and secure
fi replace using nailing tabs provided on fi replace sides.
Secure with screws or nails into BACK of framing studs.
• Kiva-style arch dimensions: Maximum depth equals
5 in. (includes finish wall surface). Minimum depth
equals 3 in. - 3/32 in.
NOTICE:
Previous numbers are for combustible construction
numbers. Arch may protrude up to 5-1/2 inches maximum
as measured from appliance front face.
NOTICE:
The kiva-style arch depth may be any size if
using noncombustible materials i.e. concrete, steel, plaster,
etc.
• A template is provided on appliance shipping carton.
Simply cut along the line and use as a template when
constructing kiva-style arch (see Figure 13.6).
NOTICE:
Template for kiva-style arch represents MINIMUM
inside dimensions. When constructing kiva-style arch, you
must add thickness of
fi
nishing materials to achieve proper
size of
fi
nished arch.
5 INCH
MAXIMUM
DEPTH
INCLUDING
WALL FINISH
MATERIAL
OPTION B: Kiva-style Arch
The second installation option requires the construction
of a kiva-style arch. This option recesses the appliance
into the wall such that construction of a hearth is not
necessary (see Figure 13.5).
Note: A 1/2 inch clearance must be maintained between
combustible materials and the front face of the fi replace.