Heat & Glo • Bravo • 704-902 Rev. J • 10/10
43
BACKING
MATERIAL
KIVA-STYLE ARCH
STRUCTURE
FINISHING
MATERIAL
Figure 13.6 Kiva-style Arch Installation
• Inside of the kiva-style arch can be finished using
combustible materials. For example, thin drywall may
be layered to form around curved arch.
OPTION C: SOUTHWESTERN kiva-style
The third installation option illustrated is a corner-installa-
tion with custom fi nishing. This option requires advanced
fi nishing methods involving either combustible or non-com-
bustible construction materials (see Figure 13.7).
• A template is provided on the appliance shipping carton.
Simply cut along the line and use as a template for
construction purposes.
• The cardboard template provided represents MINIMUM
inside dimensions of the fi nished wall surface.
• If fi nishing with plaster or drywall, a fi nish edge trim is pro-
vided around door front on appliance. Finishing materials
MUST not extend inside of the fi nish edge trim.
NOTICE:
Finishing materials cut inside the provided
template will cause the door not to
fi
t.
WARNING! Risk of Fire!
Follow minimum speci
fi
ed
clearances found in Section 16, (Appliance Dimensions
Diagram) and on
fi
replace exterior if using combustible
framing materials.
Figure 13.7 Corner Kiva Installation