background image

Hearth & Home Technologies  •  IFT-RC400 & IFT-ACM Installation Instructions  •  2326-982 Rev. Q  •  4/21

10

*=Optional Feature

Lights*

If your appliance is equipped with lighting features, use 

this function to adjust them to your desired intensity.  The 

lights can be adjusted whether the flame is on or off.

Power Vent*

Power Vent technology makes it possible to install a gas 
appliance virtually anywhere.  The Power Vent is a fan 
powered accessory that pulls exhaust from the appliance 

providing longer and more flexible venting configurations. 

A Power Vent is a standard accessory on some products 

and an option on others.  When a Power Vent is detected, 

a pre-purge of 120 seconds is automatically required. 

 

During this time, the power icon is temporarily replaced 

with 2MIN, 90s, 60s, and 30s, denoting the countdown 

until the appliance turns on.  All other functions, except 

for  TURN  FLAME  OFF  are  disabled  during  this  time.

   

The Power Vent is always ON when the flame is ON.  
When  the  flame  is  turned  off,  a  post-purge  time  of 

approximately 20 minutes will occur.

Cold-climate function and battery backup are disabled if 
a Power Vent is used.

Fan Speed*

If  your  appliance  is  equipped  with  the  fan  feature,  use 

this function to increase or decrease the amount of heat 
released into your room.  A built-in delay timer will turn 
the fan on three minutes after your appliance has been 
running to prevent cool air from being pushed into the 

room. If the flame is turned off with the fan ON, the fan 

will continue to run for 12 minutes then shutdown as long 

as the flame stays off. 
Your  appliance  will  remember  the  previous  fan  speed 

setting and automatically adjust to that level 3 minutes 
after start-up.

Timer

For your convenience a timer can be set up to 180 min-

utes to turn off your fireplace. The timer will turn the flame 

off automatically at the selected preset time.

To  use  the  timer  function,  press  “Timer”  on  the  main 

screen, select time by using up and down arrows, then 

press ON.  To turn the timer off , select timer from main 

screen and select OFF.

Child Lock

Diagnostics Menu

Tap anywhere in the gray indicator bar area to display all 

functions below.  When red, it indicates an error has been 

detected.

FUNCTIONS

FUNCTIONS

Cold Climate

Temperature Display

You can toggle the temperature display between °F and 

°C by tapping on the Room Temperature area.

HOT

This indicates that the appliance is still hot, even when the 

appliance is off.

This function turns on a small pilot flame and keeps the 

air inside your appliance warm while not in use. It is a 
useful feature in colder weather to minimize condensa-
tion on the appliance glass.  

Note:

  This feature is disabled when a Power Vent is 

installed on the appliance.

Note:

  The continuous pilot will automatically turn OFF 

after 166 hours if appliance is not actively used.  If Flame 

ON is activated before 166 hours, the automatic timer will 

re-start.

A child lock is available underneath the battery cover.  When 

the lock is enabled, the screen will lock and no functions can 

be selected.  

INDICATORS

INDICATORS

Remote Control 
Battery 

Remote control battery life indicator. If the batteries on 

your  remote  are  low,  a  notification  will  display  on  the 

screen asking you to ‘Replace Remote Batteries’ or ‘Must 

Replace Remote Control Batteries to Operate Appliance.

 

 
Refer to Replace Remote Batteries Section.  

Note:

   To  extend  the  time  between  changing  batteries, 

Lithium Ion and rechargable NiMN AAA batteries can be 

used. 

Sorry your appliance did not start.

Try again by pressing Flame On.

Your appliance did not start during the last Flame On 

command.  Verify that you have power and gas to your 

appliance.  Press the Turn Flame ON icon again, verify 

that the appliance accepts command with an audible 

beep, and turns on the flame within 90 seconds.  

Summary of Contents for IntelliFire Touch IFT-ACM

Page 1: ...nce Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions Installation and use of any damaged system component Modification of the system component Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Any such action may cause a fire hazar...

Page 2: ...as supplied in your power vent kit into the three male pins on the IFT ACM See Figure 4 6 Connect the IFT ACM to the IFT ECM by aligning the pins and tabs and pushing the IFT ACM onto the IFT ECM until both tabs latch in place Ensure the IFT ECM and IFT ACM are aligned with each other and fastened securely See Figure 3 Figure 3 Connecting IFT ACM and IFT ECM WARNING Risk of Shock DO NOT touch male...

Page 3: ...the junction box has power See Figure 4 9 Move the three position switch on the IFT ECM to the REMOTE position The green LED will blink three times A few seconds later an audible beep will oc cur to indicate that the system is ready 10 Set the RC400 face down on flat surface when install ing batteries DO NOT touch the screen during bat tery installation or removal 11 Remove the battery cover from ...

Page 4: ...audible beep will be heard from the IFT ECM 3 If the pairing is unsuccessful repeat steps 1 2 Note If additional components are added such as blowers lights or Power Vent after initial pairing the pairing process must be repeated again to detect additional components NOTICE Only one IFT RC400 remote control and one IFT RC150 wireless wall switch can be programmed into an IFT ECM To program both an...

Page 5: ...ure 8 Figure 8 Pairing Remote If the Now pairing remote to product icon occurs 1 Verify that all the wire connections are complete and verify that the ACM is powered by 120V 2 On the IFT ECM move the ON OFF REMOTE switch to the REMOTE position The green LED will blink three times A few seconds later an audible beep will occur to indicate that the system is ready 3 Remove the battery cover and inst...

Page 6: ...he filled circles For best results use a stylus You will be prompted to repeat this clockwise around the four corners of the screen Figure 12 Touch and Release 5 After touching and releasing this last point the following screen appears Figure 13 Touch and Release 6 Touch screen anywhere to return IFT RC400 to normal screen display Figure 14 Touch anywhere on the Screen 3 With RC400 software versio...

Page 7: ...ERY PACK BLK RED BRN ORANGE PILOT GREEN MAIN IFT RC400 REMOTE CONTROL GRN WHT BLK RED BLK RED BLK BLK RED IFT RC150 WIRELESS WALL SWITCH OPTIONAL OPTIONAL OPTIONAL APPLIANCE ON OFF CONTROL BRN BLK WIRE ASSEMBLY MODULE RESET SWITCH OPTIONAL ON SOME MODELS ONLY SPLITTER BLK RED I Wiring Diagram IntelliFire Touch System Wiring Diagram without Power Vent Figure 15 IFT RC400 Wiring Diagram without Powe...

Page 8: ...PTER I S 6 PIN RED BLK ORANGE PILOT GREEN MAIN GRN WHT BLK RED BLK RED BLK OPTIONAL OPTIONAL IFT RC400 REMOTE CONTROL RED BLK BRN BRN JUMPER WIRE BRN WIRE ASSEMBLY MODULE RESET SWITCH OPTIONAL ON SOME MODELS ONLY ACCESSORY CABLE POWER VENT OPTIONAL I Wiring Diagram continued IntelliFire Touch System Wiring Diagram with Power Vent Figure 16 IFT RC400 Wiring Diagram with Power Vent ...

Page 9: ... row keys and press ON to confirm the setting The actual room temperature RT measured by your IFT RC400 remote will be displayed in the upper right corner of the main menu screen To turn the thermostat function off simply select thermostat on the main menu screen and select OFF If the RT cools to more than 2 F lower than the ST for at least 2 minutes then your appliance will automatically turn ON ...

Page 10: ...mer will turn the flame off automatically at the selected preset time To use the timer function press Timer on the main screen select time by using up and down arrows then press ON To turn the timer off select timer from main screen and select OFF Child Lock Diagnostics Menu Tap anywhere in the gray indicator bar area to display all functions below When red it indicates an error has been detected ...

Page 11: ...ower source in the event of a power outage Batteries should not be used as a primary long term power source Note Battery backup is not available if a Power Vent is installed Your remote control is not able to communicate with your appliance Verify that you have power to your appliance If there is a power outage verify that appliance battery backup is fitted with new batteries After taking these ac...

Page 12: ...s and hold a paperclip type object in the P button hole for at least 10 seconds 3 Double beep from the remote will indicate that the remote will reset the 300 hour maintenance reminder If the remote 300 hour maintenance message does not clear on the first try repeat above steps To reset the 300 hour maintenance reminder if the RC400 displays the following message 1 Wake up your remote control disp...

Page 13: ...n front of it The remote acts as the thermostat mode room temperature sensor IFT RC400 is placed in the path of an air draft or vent Move the IFT RC400 away from the direct path of air flow The remote acts as the thermostat room temperature sensor Flame Modulation The IFT system is designed to automatically adjust the flame intensity based on the difference between the desired room temperature and...

Page 14: ...flame modulation will result in more control of the tem perature but will cause the appliance to cycle OFF ON less The appliance turns OFF the flame after extended periods of operation 9 hour safety shutdown timer This is normal behavior The appliance has a safety timer that will automatically turn OFF the flame after nine hours of unin terrupted operation IFT RC400 does not pair or unpair from th...

Page 15: ... previous symptom Fan is not plugged into IFT ACM Check wiring and connections Spade connectors are miswired Some Fans may be connected to the IFT ACM using spade con nectors For safety turn off the power to the appliance and check to see if the wires on either end of the spade connector do not match in color as they might be miswired IFT RC400 display the following message on screen Call Dealer E...

Page 16: ...l switch is NOT available if a Power Vent is used 3 The Pilot button on the IFT ECM activates the Cold Climate function of the fireplace This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool high humidity ambient conditions To activate the Cold Climate IFT ECM Detailed Operating Instruction CAUTION Risk of burns Appliance surfaces are hot wh...

Page 17: ...n OFF position Verify IFT ECM slider switch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system wiring or wiring harness Verify system wirin...

Page 18: ...noid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harn...

Page 19: ...ever there is no guarantee that in terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation b...