IX. TROUBLE SHOOTING
WHEN TO CALL FOR HELP
This treadmill is designed with user safety as the number one priority. In the event of
electrical failure, the treadmill will shut off automatically to prevent user injury and to
prevent damage to expensive components such as the motor.
When you encounter unusual behavior from the treadmill, simply go to the front of the
treadmill and turn the power switch off and on to reset the treadmill. This should clear
incidental errors and ready the treadmill for normal operation again.
If you have reset the treadmill by turning the power switch off and on again, and the
treadmill is still not operational, then it is time to call your dealer for service.
TROUBLE SHOOTING GUIDE
Problem
Potential cause
Corrections
Treadmill will not Dial
Switch
1.
Not plugged in
2.
Safety tether key not
inserted
3.
House
circuit
breaker
tripped
4.
Treadmill circuit breaker
tripped
5.
Switch on OFF
1.
Plug into grounded outlet.
2.
Insert safety tether key
into console.
3.
Reset or replace fuse.
4.
Lubricate treadmill deck
and reset.
5.
Turn switch to ON
Running belt slips
1.
Running belt not tight
enough
2.
Drive belt not tight enough
1.
Adjust
running
belt
tension
2.
Adjust drive belt tension
Running belt hesitates
when stepped on
1.
Insufficient lubrication
2.
Running belt too tight
1.
Apply silicone lubricant
2.
Adjust
running
belt
tension
Running
belt
is
off
centered
Running belt tension not even
across the rear roller
Center the running belt