7 Cleaning and servicing the heating system – Procedure
55
6.
Have a container ready for the pellets.
7.
Undo the four screws of the inspection hatch (1) and remove
them.
8.
Remove the pellets and dust from the reservoir.
9.
Remove the dust in the on the flap (2) of the delivery unit and the
proximity switch (4) with a vacuum cleaner.
10.
Check that the flap (2) moves smoothly.
11.
Ensure that the entire surface of the flap (2) touches the seal (3).
4.
Pull out the mains plug (1).
Figure 7/20 - Removing the mains plug
1
5.
Undo the four screws and
remove the lower front
cladding (1) of the reservoir.
Figure 7/21 - Removing the lower front cladding
1
Figure 7/22 - Checking and cleaning the reservoir and flap of the delivery unit
1
4
2
3