H B X Z O N - 0 6 0 0 Z o n e C o n t r o l
V e r s i o n 1 . 0 . 0
Page 5
ZON-0600 Installation
The ZON-0600 is designed to be wall mounted or installed in a separate electrical
enclosure. The unit should be installed indoors and protected from falling water and high
humidity conditions. With all the covers in place, it is designed to protect any individual
from accidental electrical shock. It is not suitable for installation in hazardous locations
and should not be close to any electromagnetic fields.
• Identify the four mounting holes on the ZON-0600, mark on the wall the desired
location of mounting
• Pre-drill, anchor and fasten the two bottom screws for mounting
• Hang ZON-0600 and fasten the top two screws then tighten the bottom screws
• Complete wiring connections in accordance with local area electrical codes
Installation
Connect the THM-0600 thermostat to the control. If you are using a single thermostat, ensure it is connected to
TH1 on the control. It is normal for the thermostat to take up to two (2) minutes to startup. The THM-0600 should
not be installed in a high humidity location or where falling water is located.
Thermostat field signal wiring installation
The signal wiring that connects the ZON-0600 to each thermostat should not run parallel for any lengths with
any other wires. If this is a retrofit installation and the thermostat signal wiring installation can not be verified it is
recommended that the thermostats to be installed in the mechanical room with remote room (029-0022, not
provided) and/or floor sensors (029-0045).
MOUNTING
HOLES
INSTALLATION
STAND ALONE SYSTEM SETUP
THM-0600
0
4
3
I
TT1
0
6
5
I
TT2
5
TH1
10
9
6
5
12
11
6
5
14
13
6
5
16
15
6
2
Y
G
20
19
2
X
21
2
1
2
1
1
W R
0
8
7
I
TT3
1
18
17
1
EXT
THM
TH2
TH3
TH4
Wiring polarity is important. Match
the ground and TH on the THM-
0600 to the ZON-0600 control.
The THM-0600 is the only
approved thermostat to be
with the ZON-0600. Do not
supply external power to the
thermostat.