© 2014 HBX Controls
8
Dual Mode: Floor Maximum
The thermostat will not allow the temperature in
the floor to go above this value, protecting the
integrity of the floor covering.
1) WEEKDAY
2) WEEKEND
3) HOLD TEMP
OFF
4) MODE
DUAL
5) FLOOR MAX
78°F
6) FLOOR MIN
69°F
ADJUSTMENTS
Dual Mode: Floor Minimum
The thermostat will not allow the temperature in
the floor to go below this value, protecting the
integrity of the floor covering. If in a 2 stage heating
mode, only the radiant heating contact is turned
off.
1) WEEKDAY
2) WEEKEND
3) HOLD TEMP
OFF
4) MODE
DUAL
5) FLOOR MAX
78°F
6) FLOOR MIN
69°F
ADJUSTMENTS
Dual Mode: Sensor 1
This option will be automatically set to floor sensor.
4) MODE
DUAL
5) FLOOR MAX
78°F
6) FLOOR MIN
69°F
7) SENSOR 1
FLOOR
8) SENSOR 2
NONE
9) TIME
5:18AM
ADJUSTMENTS
Dual Mode: Sensor 2
FL/Ave
- Averages external 1 + 2 using floor temperature.
Outdoor
- Will use external 2 sensor to display
outdoor
temperature.
Room
- Disregards internal sensor, uses external
sensor 2.
4) MODE
DUAL
5) FLOOR MAX
78°F
6) FLOOR MIN
69°F
7) SENSOR 1
FLOOR
8) SENSOR 2
NONE
9) TIME
5:18AM
ADJUSTMENTS
Dual Mode: Continuous Fan
ON: Enables the fan to run continuously, regardless of
whether the thermostat is calling for heat or cooling
Int Fan ON/OFF: This setting will set the ON/OFF Time
for the intermittent fan
Ex: The fan will come on for 15min every 2h. Set (Int
Fan ON: 15min) & (Int Fan OFF: 2h)
This option is not applicable to 2 Heat/Cool,
2 Cool/Heat or Boiler Modes.
5) SENSOR 1
ROOM
6) SENSOR 2
ROOM
7) CONT FAN
INT
8) INT FAN OFF 2H
9) INT FAN ON 15M
10) TIME
10:20
ADJUSTMENTS
Time
Set the time for your appropriate time zone
.
4) MODE
ROOM
5) SENSOR1
NONE
6) SENSOR2
NONE
7) CONT FAN
OFF
8) TIME
5:53am
9) DAY
MON
ADJUSTMENTS
Day
Setting the appropriate day is important in
regards to the programmable features. Setback
features rely on the applicable day being set.
If the floor temperature goes above its max when in
2 stage heating mode, but the room temperature is
not satisfied, stage 1 heat will turn off
3) HOLD TEMP
76°F
4) MODE
ROOM
5) SENSOR1
NONE
6) SENSOR2
NONE
7) CONT FAN
OFF
8) TIME
5:53am
ADJUSTMENTS