background image

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

 

Page 2 of 16 

Max-Flo™ PUMP Series 

IS2800X5  Rev. C 

IMPORTANT SAFETY INSTRUCTIONS

 

 

 

 

WARNING

 – 

READ AND FOLLOW ALL INSTRUCTIONS

 

in this owner’s manual and on the equipment. Failure to follow instructions can cause severe injury and/or death

 

WARNING

 

– Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause severe injury 
and/or death due to the following entrapment hazards: 

Hair Entrapment

- Hair can become entangled in suction outlet cover. 

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked, 

missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.  

Evisceration/ Disembowelment 

- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or 

suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment. 

Mechanical Entrapment

- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a 

suction outlet cover resulting in mechanical entrapment.

 

 

WARNING

 

To Reduce the risk of Entrapment Hazards:

 

o

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be 
installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’)  [1 meter]  apart, as 
measured from near point to near point. 

o

 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

o

 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

o

 

The maximum system flow rate shall not exceed the flow rating of as listed on Table 1. 

o

 

Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 

o

 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

o

 

In addition two or more suction outlets per pump installed in accordance with latest ASME, APSP Standards and CPSC 
guidelines, follow all National, State, and Local codes applicable. 

o

 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 

WARNING

 

 

Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the 

suction outlets can result in an increase potential for suction entrapment as described above.

 

 

WARNING

 

– Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and 

other material can result in an increase potential for suction entrapment as described above.

 

 

WARNING

 

– Suction outlet components have a finite life, the cover/grate should be inspected frequently and 

replaced at least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 

CAUTION

 

– Components such as the filtration system, pumps and heater must be positioned so as to prevent 

their being used as means of access to the pool by young children.

  

 

WARNING 

– Never operate or test the circulation system at more than 50 PSI.

 

 

WARNING 

– Never change the filter control valve position while the pump is running.

  

 

WARNING

 

– 

To reduce risk of injury, do not permit children to use or climb on this product.  Closely supervise children at all 

times.  Components such as the filtration system, pumps, and heaters must be positioned to prevent children from using them as a means of 
access to the pool. 

Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause 

severe injury and/or death. 

 This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of 

the following signal words and be alert to the potential for personal injury. 

 

WARNING 

warns about hazards that 

could 

cause serious personal injury, death or major property damage and 

if ignored presents a potential hazard. 

 

CAUTION 

warns about hazards that 

will 

or 

can 

cause minor or moderate personal injury and/or property 

damage and if ignored presents a potential hazard.  It can also make consumers aware of actions that are 
unpredictable and unsafe.   

The 

NOTICE 

label indicates special instructions that are important but not related to hazards.

 

 

 

 

 

 

 

 

 

Summary of Contents for Max-Flo SP2805X7

Page 1: ...in ground swimming pool spa that is equipped with large capacity filters heaters and pool cleaning equipment The Max Flo is a self priming pump that incorporates an improved seal and impeller design t...

Page 2: ...ely attached suction outlet components immediately o In addition two or more suction outlets per pump installed in accordance with latest ASME APSP Standards and CPSC guidelines follow all National St...

Page 3: ...uipment can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to all electrical equipment be...

Page 4: ...actical and run suction lines as direct as possible to reduce friction loss Suction lines should have continuous slope upward from lowest point in line Joints must be tight but not over tightened Suct...

Page 5: ...the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force hose connector fitting past this stop It is only necessary to tig...

Page 6: ...und terminal to electrical service ground Bond motor to pool structure Bonding will connect all metal parts within and around the pool with a continuous wire Bonding reduces the risk of a current pass...

Page 7: ...pump and piping system using filter manual air relief valve See filter owner s manual for more details 4 If water source is higher than the pump pump will prime itself when suction and outlet valves...

Page 8: ...cover from strainer housing 3 Disconnect pump from mounting pad wiring system after power has been turned OFF and piping system 4 Once the pump is removed of water re install the strainer cover and d...

Page 9: ...t locations 8 Clean and lightly lubricate the impeller hub and seal recess in the seal plate with a dilute solution of non granulated liquid type soap 9 Gently wipe the black polished surface of the s...

Page 10: ...1 SPX1600R SPX1600R SPX1600R SPX1600R SPX1600R 8 DIFFUSER 1 SPX2800B SPX2800B SPX2800B SPX2800B SPX2800B 9 IMPELLER 1 SPX2605C SPX2607C SPX2610C SPX2615C SPX2610C 10 SEAL ASSEMBLY 1 SPX1600Z2 SPX1600Z...

Page 11: ...ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is locked firmly in position Lubricant will help to creat...

Page 12: ...d suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction condition or throttle return lines if practical Holding hand over return fi...

Page 13: ...r the nearest Hayward Authorized Service Center For assistance on your nearest Hayward Authorized Service Center please visit us at www haywardpool com Hayward shall not be responsible for cartage rem...

Page 14: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 14 of 16 Max Flo PUMP Series IS2800X5 Rev C THIS PAGE INTENTIONALLY LEFT BLANK...

Page 15: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 15 of 16 Max Flo PUMP Series IS2800X5 Rev C THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...tions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LINE AT WWW HAYWARDNET COM DETACH HERE Fill out bottom portion completely and...

Reviews: