84
2420331900 E06.14
EN
Telescopic machines, 21 - 25 m
F
- Special procedure
6.4 -
PRE-OPERATION INSPECTION
• If any item on the checklist is marked NO during the inspection; machine must be tagged and locked out
and placed out of service.
• DO NOT operate the machine until all identified items are corrected and it has been declared safe for
operation.
Description
Yes
No
Perform all specified machine functional tests
• All machine functional tests result positive
Start the machine from platform control panel
Switch OFF all emergency push button
• Check absence of warning signal
• Check that the green indicator of the electrical box is switched on
Performs the secondary guarding system tests for each movement specified in the table hereinbelow
• Push the switch bar while operating the specified movement
• Check what movement are authorized and complete the table
• Check that visual and audible warning are activated
• Check that the reset button of the electrical box is illuminated
• Push the reset button
• Check that normal operation is restored
Operated movement when the bar is triggered
Driving
Rotation
Lifting or
telescope
extension
Other
movements
Move forward
Move backward
Left
Right
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Platform
control box
Forward
drive
Reverse
drive
Turntable left
Turntable
right
Lifting or
telescope
extension
Boom
descent and
retraction
telescope
Other
movements
Lower
control box
All
Summary of Contents for H21TX
Page 2: ...2 2420331900 E06 14 EN Telescopic machines 21 25 m...
Page 6: ...6 Operator s manual...
Page 10: ...10 2420331900 E06 14 EN Telescopic machines 21 25 m...
Page 43: ...A B C D E F G H I 43 2420331900 E06 14 EN Telescopic machines 21 25 m C Machine layout...
Page 70: ...70 2420331900 E06 14 EN Telescopic machines 21 25 m E Driving...
Page 86: ...86 2420331900 E06 14 EN Telescopic machines 21 25 m F Special procedure...
Page 104: ...104 2420331900 E06 14 EN Telescopic machines 21 25 m H Intervention register...