A
B
C
D
E
F
G
H
I
33
2420331900 E06.14
EN
Telescopic machines, 21 - 25 m
C
- Machine layout
Specific labels ANSI
Specific labels, optional
4.1.5 - Green labels
4.1.6 - Blue labels
N.B.
-:-The blue labels indicate information or a precaution to be taken in case of danger.
Green labels indicate maintenance, operations or information ( CSA standard).
A29
A22
A25
O3
A27
Minimum safe approach distance
(M.S.A.D) to energized (exposed or
insulated) power lines
Voltage Range
(Phase to phase)
Minimum safe approach distance
0 to 300 V
Over 300 V to 50 kV
Over 50 kV to 200 kV
Over 200 kV to 350 kV
Over 350 kV to 500 kV
Over 500 kV to 750 kV
Over 750 kV to 1000 kV
AVOID CONTACT
10
15
20
25
35
45
3.05
4.60
6.10
7.62
10.67
13.72
3078147890 c
(Feet)
(Meters)
A8
R18
A31
Summary of Contents for H21TX
Page 2: ...2 2420331900 E06 14 EN Telescopic machines 21 25 m...
Page 6: ...6 Operator s manual...
Page 10: ...10 2420331900 E06 14 EN Telescopic machines 21 25 m...
Page 43: ...A B C D E F G H I 43 2420331900 E06 14 EN Telescopic machines 21 25 m C Machine layout...
Page 70: ...70 2420331900 E06 14 EN Telescopic machines 21 25 m E Driving...
Page 86: ...86 2420331900 E06 14 EN Telescopic machines 21 25 m F Special procedure...
Page 104: ...104 2420331900 E06 14 EN Telescopic machines 21 25 m H Intervention register...