35
Art. Nr.: 5090032065
Rev.: 03/2018-09-25
MSH Basic-FUBO-E-SR4 / MSH Basic-MBK-R4
EN
►
Positioned and stable MSH Basic-FUBO-E-SR4 mount-
ed vertically, aligned with the batter board and fi lled
with sand (see Fig.: 20).
IMPORTANT!
No sealing due to incorrect preparation of installation!
Incorrect preparation can result in damage.
• The upper edge of the fi nished fl oor always has to be above the red marking.
• In buildings without a fl oor structure the red frame corresponds to the upper edge of the
unfi nished fl oor. The basic unit is shortened by removing the individual compensation
frames; this is only possible up to the red marking
(the compensation frame with the
red marking may not be removed)
. Later reworking is not applicable if the upper edge
of the basic unit is aligned with the upper edge of the fi nished fl oor.
►
Concreted basic unit MSH Basic-FUBO-E-SR4.
Fig.: 20
Legend for Fig.: 21
1
Finished fl oor height
Fig.: 21