MSH Basic-FUBO-E-SR4 / MSH Basic-MBK-R4
EN
MPORTANT!
No sealing due to incorrect preparation of
installation!
Incorrect preparation can result in damage.
• On the MSH Basic-FUBO-E-SR4 (basic unit) there
is a label/marking "Upper edge
of unfi nished
fl oor" (see Fig.: 14)
.
• The 3-ribbed seals must always be located in the
unfi nished fl oor concrete plate.
• The water barrier fl ange from the ground spike
may not be at the same height as the 3-ribbed
seal of the casing pipe for reasons of space.
10
Abb.: 14
If the fl oor structure is higher than
235 mm
, the 3-ribbed
seals on the pipes and the water barrier fl ange on the
installation fi xture are pushed down evenly so as to ensure
that the 3-ribbed seals and water barrier fl ange are at the
level of the unfi nished fl oor.
The yellow marking
"unfi nished fl oor upper edge"
is
irrelevant here (see Fig.: 16).
Fig.: 16
IMPORTANT!
No sealing due to incorrect preparation of
installation!
Incorrect preparation can result in damage.
• After connecting the pipes, check the bend
radii R ≥ 1 m.
►
MSH Basic-FUBO-E-SR4 (basic unit) with inserted KES
hose systems (see Fig.: 15).
Fig.: 15