EPA CERTIFIED ENGINES
2L41C, 2M41, 2M41Z
108
HATZ
Operator’s Manual
Assembly:
▪ Assemble in reverse sequence.
▪ Make sure that all parts are correctly placed and tightened.
▪ Use anti-seize compound
J
as specified by HATZ.
SAMPLING OF EXHAUST EMISSIONS
After the engine is installed in the equipment and placed in service, the sam-
pling of exhaust emissions can be performed in a way that prevents diluting
the exhaust sample with ambient air as follows:
Specification: Adding a 20-centimeter bended extension to the exhaust pipe.
Engine type
Ø d (mm)
HATZ-Ident. Nr.
Clamp
HATZ-Ident. Nr.
2L41C
48
0000 038 775 00
0000 504 103 01
2M41
55
0000 038 776 00
0000 038 778 00