2L41C, 2M41, 2M41Z
Faults
HATZ
89
Operator’s Manual
The starter does not switch on and the engine does not turn.
Possible causes
Remedy
Chapter
Irregularities in the electrical equipment:
Battery and/or other
cable connections are
incorrectly connected.
Check the electrical equipment
and its components or contact
Hatz service.
3.2.4 Electrical
equipment, page
18
Cable connections are
loose and/or oxidized.
Battery is faulty and/or
not loaded.
Faulty starter.
Faulty relay, monitor-
ing elements, etc.
The engine starts, but does not continue running after the starter is
switched off.
Possible causes
Remedy
Chapter
The speed control
lever is not sufficiently
set in the Start direc-
tion.
Set the lever to the Start posi-
tion.
7.4 Setting the
speed control,
page 36
Machine is not uncou-
pled.
If possible, separate the engine
from the machine by uncou-
pling it.
Fuel prefilter is
clogged.
Change the fuel prefilter.
8.2.10 Changing
the fuel prefilter,
page 69
Main fuel filter is
clogged.
Change the main fuel filter.
8.2.15 Change
the main fuel fil-
ter, page 79
Fuel supply is inter-
rupted.
Systematically check the entire
fuel supply.
Stop signal from monitoring elements that are associated with the au-
tomatic switch-off (optional):
▪ No oil pressure.
Check the oil level.
7.8 Check the oil
level, page 49
▪ Faulty three phase
alternator.
Contact Hatz service.
Summary of Contents for 2L41C