INSTRUCTIONS ON THE INSTALLATION OF THE EXHAUST SYSTEM
Following are the instructions to properly install the exhaust system and re-
lated components consistent with the EPA emission regulation requirements.
2M41, 3M41, 4M41
2
1
5
6
3
4
Exhaust-silencers
The exhaust silencer is fitted in connection with gaskets.
Fixation is done by hexagon head screws (1) and Allen screws (3).
Dismantling:
▪ Remove in numerical sequence (1...5).
Assembly:
▪ Assemble in reverse sequence.
▪ Use anti-seize compound
J
as specified by HATZ.