Maintenance
2L41C, 2M41, 2M41Z
82
HATZ
Operator’s Manual
Pos.
Designation
1
Red field
2
Reset button
3
Hose
4
Air filter maintenance display
Ignition lock
0
Off
I
Operation
II
Start
Procedure
Step
Activity
1
Remove the capsule hood and the side panel trim (see the
chapter
).
2
Turn the starting key to position I.
3
Pull the hose (3) off of the exhaust manifold.
Electrical air filter maintenance display
4
Generate a vacuum by sucking forcefully at the hose end.
The indicator (5) lights up.
5
If there is no reaction, check the following:
▪ Electrical part; cable connections, etc.
▪ Indicator
▪ Function of the maintenance switch.
Mechanical air filter maintenance display
4
Generate a vacuum by sucking forcefully at the hose end.
The red field (1) engages.
5
After the function test, unlock the red field (1) by pressing the re-
set button (2).
After the function test
6
Replace the faulty parts.
7
Reattach the hose (3) of the exhaust manifold.
8
Mount the capsule and air guide parts again.
Summary of Contents for 2L41C
Page 2: ......