Hatsuyuki HB310B2 User Manual Download Page 14

DAILY MAINTENANCE

5

MAINTENANCE

Be  sure  the  unit  is  switched  off  and 

unplugged  before  cleaning.  Wear 

protective  gloves  when  cleaning  the 

inside  of  the  chamber  and  when 

changing  blades.  Do  not  touch  the 

blade tip directly.

Lower the blade below the conical case 

surface when cleaning the inside of the 

chamber.  Wipe  the  shaving  table 

counterclockwise  (against  the  blade  tip 

direction).

Do  not  immerse  the  unit  in  water.  This 

could  cause  an  electrical  short  circuit, 

rust, or permanent damage to the unit.

   WARNING

Do not touch the power switch, plug, or 

other electric parts with wet hands. 

Remarks

Inside Ice Shaving Chamber (including the shaving 

table, slide cover etc.):

1) Turn  the  blade  adjustment  knob  completely 

clockwise to lower the blade behind the surface of 

the  shaving  table.  With  the  blade  above  the 

shaving table, it could injure your fingers. 

2) Turn the slide cover counterclockwise to open it.

3)   Clean  the  shaving  table  using  a  damp  cloth  in  a 

counterclockwise  direction.  Do  not  clean  in  a 

clockwise  direction;  this  could  cause  injury 

inflicted by the blade.

4) Clean  the  inside  of  the  slide  cover  using  a  damp 

Do  not  use  water  over  40

°

  Celsius  when  cleaning. 

This  could  cause  the  plastic  parts  to  become 

distorted.

Do not use the followings on plastic parts: benzine, 

alcohol,  petroleum,  powdered  soap,  polishing 

powder,  alkaline  detergent,  acid,  hypochlorous 

acid, scrub brushes, etc. When a chemical cloth is 

used  for  this  machine,  follow  the  instruction 

manual of the chemical cloth.

Summary of Contents for HB310B2

Page 1: ...NSFER RE SALE OF MACHINE Before operating this machine please read and understand the instructions speci ed in this manual for proper and safety use Retain this manual for your immediate and future re...

Page 2: ...tric bleed ing or electric shock Dedicated Exclusive use outlet Always use an outlet dedicated to each machine Never use exten sion cords or connect the unit to other power supply cords Never connect...

Page 3: ...t circuit or electric shock as well as rust and other water related problems Do not damage power supply cord Never work on power cord and never pull twist or bundle it Do not place a heavy things on i...

Page 4: ...orks Never touch blades directly They are very sharp and can cause injury Never try to disassemble or repair the machine by yourself Always call a quali ed technician Incorrect repair will likely caus...

Page 5: ...perfect installation can cause the unit to tip or fall and is therefore dangerous Install the machine in a location una ected by occasional dripping of water Melting ice will drip and can therefore dr...

Page 6: ...cause of illness Grip the ice block rmly The ice could jump out if it is not positioned rmly Do not touch the prongs with your ngers Doing so could cause injury Adjust the tension bolt properly so th...

Page 7: ...from a block of ice a dice of 13 cm approx Use a block of ice and never use other items Shaving Chamber Hose Connector Blade Blade Adjustment Knob Shaving Table Main Shaft Power Switch Crank Handle Cr...

Page 8: ...not produce soft and u y shaved ice It could damage the blade tip and the blade will not shave the ice Use transparent ice for soft and u y shaved ice 2 Do not put things on the unit The main shaft t...

Page 9: ...it is not closed properly the unit will not work even though it has been turned OPERATION INSTRUCTIONS 1 Plug in the machine Make sure the power switch is turned to the o position before plugging in t...

Page 10: ...xture of the shaved ice Turn the blade adjustment knob for the desired ice texture Standard shaved ice texture is 1 millimeter mm as this is the pitch between the blade tip and the shaving table Turn...

Page 11: ...e to raise the ice holder 2 Con rm the ice holder does not descend when you remove a supporting hand from the crank handle 3 Move the sliding cover shaving shield to the right to open 4 Take the ice o...

Page 12: ...n you remove a supporting hand from the holder yet it doesn t feel heavy or tight when the handle is moved to lift the holder When the motor is overloaded the protector causes the machine to stop auto...

Page 13: ...fasten the blade But do not take o the screws 6 Remove the blade upwards through the opening of the shaving table 4 Turn the blade adjustment knob counterclockwise so that the blade tip comes out sli...

Page 14: ...ng table slide cover etc 1 Turn the blade adjustment knob completely clockwise to lower the blade behind the surface of the shaving table With the blade above the shaving table it could injure your ng...

Page 15: ...the Shaft Cover Wipe covers using a soft dry cloth Clean hardened dirt using a damp cloth and warm water A gentle dish detergent can be used Be sure to completely remove any traces of detergent with a...

Page 16: ...ined or otherwise mistreated it could be damaged This could cause a re or electric shock WARNING Check that the earth wire is not cut or disconnected from the terminal Should there be any defects cont...

Page 17: ...ntact the distributor Close the slide cover shaving shield completely Switch OFF Remove the cause Replace the blades see Page 12 Turn the blade adjustment knob clockwise to raise the blade Turn the bo...

Page 18: ...ditions The blade tip arises 1mm above the shaving table Extra Blade 1 Drip Hose 1 Gear Oil 1 Crank Handle 1 Shaft Cover 1 Crank Handle Fixing Bolt M6 x 16 with lock 1 Drain Hose Except HF 300P 1 Ice...

Reviews: