E. MAINTENANCE ALARM - CYCLE COUNT
a) Press and hold
SET
button until display shows "1", then press
UP
button until
display shows
"E"
b) Press the
SET
button again. The equipment is now in maintenance alarm
adjustment mode. The display will show "0" with a flashing dot.
c) Press the
UP / DOWN
button to select the appropriate number of cycles after
which the alarm will occur. You can choose the option "1-5".
Number "1" means that after activating the garage door 1000 times, the LED
light will flash 10 times quickly, each time the value is exceeded. At the
same time you will see the figure "t" on the display. Your garage door needs
maintenance.
The number "2" indicates that the maintenance alarm count cycle is set to
2,000 times.
The number "3" indicates that the maintenance alarm count cycle is set to
3,000 times.
The number "4" means that the maintenance alarm count cycle is set to
4,000 times.
The number "5" indicates that the maintenance alarm count cycle is set to
5,000 times.
The number "0" means that the maintenance alarm count cycle is set to 0
times.
d) Press the
SET
button to confirm the settings and the drive will automatically go
back to the ready state and display "ll".
ATTENTION!
1. The operating cycle counter is by default set to "0".
2. If "b" appears on the display and the LED is blinking 10 times quickly, it
means the door is out of balance, we strongly recommend that you
maintain your garage door.
3. "Check" or reprogram the end positions after maintenance warnings.